0600-00024 Laird Technologies, 0600-00024 Datasheet - Page 29

ANTENNA 915MHZ 1/2WV 7" RA RPSMA

0600-00024

Manufacturer Part Number
0600-00024
Description
ANTENNA 915MHZ 1/2WV 7" RA RPSMA
Manufacturer
Laird Technologies
Datasheets

Specifications of 0600-00024

Antenna Type
Whip: 1/2 Wave, Swivel, Tilt (Right Angle)
Number Of Bands
1
Frequency
902MHz ~ 928MHz
Vswr
2
Gain
2dBi
Termination
RP-SMA
Mounting Type
Connector
Height (max)
8.25" (209.5mm)
Impedance
50 Ohms
Technology Type
1/2 Wave Wireless Transceiver Antenna
Termination Style
RPSMA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Channel Number
Transmit Retries
Baud Rate High
Baud Rate Low
Stop bit Delay
Count Reload
Parameter
Product ID
Broadcast
Control 0
Attempts
Control1
Stale
EEPROM Parameters
The OEM Host can program various parameters that are stored in EEPROM which become active after a power-on reset.
Table 9 - EEPROM Parameters, gives the locations and descriptions of the parameters that can be read or written by the
OEM Host. Factory default values are also shown. Do not write to any EEPROM addresses other than those listed
below. Do not copy a transceiver’s EEPROM data to another transceiver. Doing so may cause the transceiver to
malfunction.
EEPROM
Address
0x4C
0x4D
0x00
0x3F
0x40
0x42
0x43
0x45
0x4F
0x56
(Bytes)
Length
40
1
1
1
1
1
1
1
1
1
Range
0x00 –
0x00 –
0x00 –
0x01 –
0x01 –
0x01 –
0xFF
0x2F
0xFF
0x00
0xFF
0xFF
0xFF
Table 9 - EEPROM Parameters
AC4790-200:
AC4790-1000: 0x10
AC4790-1x1:
01000011b (0x43)
Default
0xFF
0xFC
0x00
0x00
0x04
0x04
0x40
0x00
0x00
40 bytes - Product identifier string. Includes revision
information for software and hardware.
For systems using the RS-485 interface or Parity, the serial
stop bit might come too early (especially at slower interface
baud rates). Stop bit Delay controls the width of the last bit
before the stop bit occurs.
0xFF = Disable Stop bit Delay (12us)
0x00 = (256 * 1.6us) + 12us
1 – 0xFE = (value * 1.6us) + 12us
Set 0 = 0x00 – 0x0F (US/Canada): AC4790-1x1/200
Set 1 = 0x10 – 0x2F (US/Canada): AC4790-1x1/1000
Set 3 = 0x30 – 0x37 (US/Canada): AC4790-1x1-200
Low Byte of the interface baud rate. Default baud rate is
57,600.
Always 0x00
Settings are:
bit-7 – 0
bit-6 – DES Enable
0 = Disable Encryption
1 = Enable Data Encryption
bits-5 – 0: 0
Maximum number of times a packet is sent out when
Addressed Packets is selected.
Total number of times a packet is sent out when Broadcast
Packets is selected.
Determines the amount of time a transceiver will keep
another transceiver (say transceiver A) active in its Radio
Table. This counter is reset every time a packet is received
from that transceiver (A).
bit-7 – AeroComm Use Only
bit-6 – 1
bit-5 – 0
bit-4 – Auto Destination
0 = Use Destination Address
1 = Automatically set Destination to last radio received from
bit-3 – 0
bit-2 – RTS Enable
0 = RTS Ignored
1 = Transceiver obeys RTS
bit-1 – Duplex
0 = Half Duplex
1 = Full Duplex
bit-0 – Auto Config
0 = Use EEPROM values
1 = Auto Configure Values
Settings are:
(Australia): AC4790-1x1/200/1000