XIB-E Digi International/Maxstream, XIB-E Datasheet - Page 34

no-image

XIB-E

Manufacturer Part Number
XIB-E
Description
BOARD INTERFACE ETHERNET
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XIB-E

Accessory Type
Interface Board
For Use With/related Products
XStream and Xcite Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
TT (Streaming Limit) Command
VR (Firmware Version) Command
WR (Write) Command
<Networking & Security> Set/Read the number
of bytes that can be sent out before a random
delay is issued. TT Command is used to simulate
full-duplex behavior.
If a module is sending a continuous stream of RF
data, a delay is inserted (transmission is stopped,
allowing other modules time to transmit (once it
sends number of bytes specified by TT Command). Inserted random delay lasts between 1 & ‘RN
+ 1’ delay slots, where each delay slot lasts 38 ms.
<Diagnostics> Read the Firmware Version of the
module.
<(Special)> WR Command writes configurable
parameters to the module’s non-volatile memory
(Parameter values remain in the module’s
memory until overwritten by future use of WR Command).
If changes are made without writing them to non-volatile memory, the module reverts back to
previously saved parameters the next time the module is powered-on.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
AT Command: ATTT
Binary Command: 0x1A (26 decimal)
Parameter Range: 0 – 0xFFFF [bytes]
Default Parameter Value: 0xFFFF (65535d)
Number of bytes returned: 2
Related Commands: RN (Delay Slots)
Minimum Firmware Version Required: 4.22
AT Command: ATVR
Binary Command: 0x14 (20 decimal)
Parameter Range: 0 – 0xFFFF [read-only]
Number of bytes returned: 2
AT Command: ATWR
Binary Command: 0x08
34 