XBIB-U Digi International/Maxstream, XBIB-U Datasheet - Page 25

no-image

XBIB-U

Manufacturer Part Number
XBIB-U
Description
BOARD USB ZIGBEE MOD PRO
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of XBIB-U

Design Resources
XBIB-U Shematic
Accessory Type
Interface Board
For Use With/related Products
XBee and XBee Pro Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBIB-U-DEV
Manufacturer:
DIGI
Quantity:
20 000
Refer to the ‘X‐CTU’ sec‐
tion of the Develop‐
ment Guide [Appendix 
B] for more information 
regarding the X‐CTU 
configuration software.
3. RF Module Configuration
3.1. Programming the RF Module
3.1.1. Programming Examples
Refer to the Command Mode section [p24] for more information about entering Command Mode,
sending AT commands and exiting Command Mode. For information regarding module program-
ming using API Mode, refer to the API Operation sections [p54].
Setup
Sample Configuration: Modify RF Module Destination Address
Sample Configuration: Restore RF Module Defaults
The programming examples in this section require the installation of MaxStream's X-CTU Soft-
ware and a serial connection to a PC. (MaxStream stocks RS-232 and USB boards to facilitate
interfacing with a PC.)
1.
2.
3.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch.
Ensure the ‘Baud’ setting on the ‘PC Settings’ tab matches the interface data rate of the RF mod-
ule. By default, the BD parameter = 3 (which corresponds to 9600 bps).
Example: Utilize the X-CTU “Terminal” tab to change the RF module's DL (Destination Address
Low) parameter and save the new address to non-volatile memory.
After establishing a serial connection between the RF module and a PC [refer to the 'Setup' sec-
tion above], select the “Terminal” tab of the X-CTU Software and enter the following command
lines (‘CR’ stands for carriage return):
Method 1 (One line per command)
Method 2 (Multiple commands on one line)
Example: Utilize the X-CTU “Modem Configuration” tab to restore default parameter values.
After establishing a connection between the module and a PC [refer to the 'Setup' section
above], select the “Modem Configuration” tab of the X-CTU Software.
1.
2.
© 2007 MaxStream, Inc.
Install MaxStream's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file.
(The file is located on the MaxStream CD and under the 'Software' section of the following
web page: www.maxstream.net/support/downloads.php)
Mount the RF module to an interface board, then connect the module assembly to a PC.
Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity set-
tings of the Com Port match those of the RF module.
Select the 'Read' button.
Select the 'Restore' button.
Send AT Command
+++
ATDL <Enter>
ATDL1A0D <Enter>
ATWR <Enter>
ATCN <Enter>
Send AT Command
+++
ATDL <Enter>
ATDL1A0D,WR,CN <Enter>
System Response
OK <CR> (Enter into Command Mode)
{current value} <CR> (Read Destination Address Low)
OK <CR> (Modify Destination Address Low)
OK <CR> (Write to non-volatile memory)
OK <CR> (Exit Command Mode)
System Response
OK <CR> (Enter into Command Mode)
{current value} <CR> (Read Destination Address Low)
OK<CR> OK<CR> OK<CR>