XIB-R Digi International/Maxstream, XIB-R Datasheet - Page 21

no-image

XIB-R

Manufacturer Part Number
XIB-R
Description
BOARD INTERFACE RS232/485
Manufacturer
Digi International/Maxstream
Datasheet

Specifications of XIB-R

Accessory Type
Interface Board
For Use With/related Products
XStream and Xcite Radios
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q2231853
9XCite™ OEM RF Module – Product Manual v2.1 [2007.01.04]
BT (Guard Time Before) Parameter
CC (Command Sequence Character) Parameter
CD (DO3 Configuration) Command
CN (Exit AT Command Mode) Command
<Non-AT Settable Parameter: AT Command Options> BT Parameter is used to set the DI pin silent
time that precedes the command sequence character (CC Parameter). By default, 1 half of a sec-
ond (500 milliseconds) must elapse before entering another character. The AT Command Mode
Sequence used to enter AT Command Mode is as follows:
All of the values in this sequence can be adjusted. AT Command is used to adjust the period of
silence that precedes the command sequence character.
Parameter Range: 0 - 0xFFFF (x 1 millisecond)
# of bytes returned: 2
Default Parameter Value: 0x1F4 (500 decimal)
Related Commands: AT (Guard Time After), CC (Commands Sequence Character)
<Non-AT Settable Parameter: AT Command Options> CC Parameter is used to adjust the com-
mand sequence character used when entering AT Command Mode.
The AT Command Mode Sequence used to enter AT Command Mode is as follows:
Parameter Range: 0x20 - 0x7F
# of bytes returned: 1
Default Parameter Value: 0x2B (ASCII "+" sign)
Related Parameters: AT (Guard Time After), BT (Guard Time Before)
<AT Command: Serial Interfacing> Used to rede-
fine the RX LED I/O line.
<AT Command: AT Command Mode Options> CN Command allows users to explicitly exit AT Com-
mand Mode and return the radio modem into Idle Mode.
AT Command: CN
© 2007 MaxStream, Inc.
"No characters sent for 1 millisecond [BT (Guard Time Before) Parameter]
"Send three plus characters "+++" [CC (Command Sequence Character) Parameter]
"No characters sent for 1 millisecond [AT (Guard Time After) Parameter]
"No characters sent for 1 millisecond [BT (Guard Time Before) Parameter]
"Send three plus characters "+++" [CC (Command Sequence Character) Parameter]
"No characters sent for 1 millisecond [AT (Guard Time After) Parameter]
AT Command: ATCD
Parameter Ranges: 0 - 2
Default Parameter Value: 0
Number of bytes returned: 1
Parameter
0
1
2
Configuration
RX LED
High
Low
     21