CME8000-DB C-Max, CME8000-DB Datasheet - Page 18

no-image

CME8000-DB

Manufacturer Part Number
CME8000-DB
Description
BOARD DEMO FOR CME8000
Manufacturer
C-Max
Datasheet

Specifications of CME8000-DB

Module/board Type
Demonstration Board
For Use With/related Products
CME8000
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
561-1006
C-MAX
Modulation
The carrier amplitude is switched off at the
beginning of each second for a period of 100 ms
(binary zero) or 200 ms (binary one).
Exception
Bit 53, 54, 55, 56, 57, 58. For these bits, a binary
zero is defined with 200 ms, a binary one with
300ms.
CME8000
SPEC No.
:
Time Solutions
Revision
B.15
09.03.07
State
03.05.2007
C-MAX printed
Time-Code Format
The time-code format consists of 1-minute time
frames. A time frame contains BCD coded
information of year, month, calendar day, day of
the week, hours and minutes. At the switch-over
to the next time frame, the carrier amplitude is
reduced for a period of 500 ms.
The presence of the fast code during the first
500 ms at the beginning of the minute is not
guaranteed. The transmission rate is 100 bit/s and
the code contains information of hour, minute, day
and month.
English
Data Sheet
Version
CME8000
18 of 22
Page

Related parts for CME8000-DB