AD6620S/PCB Analog Devices Inc, AD6620S/PCB Datasheet - Page 11

no-image

AD6620S/PCB

Manufacturer Part Number
AD6620S/PCB
Description
BOARD EVAL DUAL RCVR W/AD6620AS
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD6620S/PCB

Rohs Status
RoHS non-compliant
Module/board Type
Evaluation Board
For Use With/related Products
AD6620
ABSOLUTE MAXIMUM RATINGS
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +4.5 V
Input Voltage . . . –0.3 V to VDD + 0.3 V (Not 5 V Tolerant)
Output Voltage Swing . . . . . . . . . . . . –0.3 V to VDD + 0.3 V
Load Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 pF
Junction Temperature Under Bias . . . . . . . . . . . . . . . . 130°C
Storage Temperature Range . . . . . . . . . . . . –65°C to +150°C
Lead Temperature (5 sec) . . . . . . . . . . . . . . . . . . . . . . 280°C
Thermal Characteristics
80-Lead Plastic Quad Flatpack:
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD6620 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
Stresses greater than those listed above may cause permanent damage to the
device. These are stress ratings only; functional operation of the device at these or
any other conditions greater than those indicated in the operational sections of this
specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
θ
θ
JA
JC
= 44°C/W
= 11°C/W
Model
AD6620AS
AD6620S/PCB
Temperature Range
–40°C to +85°C (Ambient)
ORDERING GUIDE
Package Description
80-Lead PQFP (Plastic Quad Flatpack)
Evaluation Board with AD6620AS and Software
EXPLANATION OF TEST LEVELS
I.
II. 100% Production Tested at 25°C, and Sampled Tested at
III. Sample Tested Only.
IV. Parameter Guaranteed by Design and Analysis.
V. Parameter is Typical Value Only.
VI. 100% Production Tested at 25°C, and Sampled Tested at
100% Production Tested.
Specified Temperatures.
Temperature Extremes.
WARNING!
Package
Option
S-80A
ESD SENSITIVE DEVICE
AD6620