POE36U-1AT PHIHONG USA, POE36U-1AT Datasheet - Page 3

ADPT 33.6W 1PORT IEEE802.3AT

POE36U-1AT

Manufacturer Part Number
POE36U-1AT
Description
ADPT 33.6W 1PORT IEEE802.3AT
Manufacturer
PHIHONG USA
Type
Single Port, Midspan Injectorr
Datasheet

Specifications of POE36U-1AT

Power (watts) - Per Port
33.6W
Number Of Ports
1
Voltage - Input
90 ~ 264VAC
Voltage - Output
56VDC
Current - Output
600mA
Mounting Type
Desktop
Size / Dimension
5.98" L x 2.56" W x 1.42" H (152mm x 65mm x 36mm)
Input Connector
IEC320-C14
Efficiency
78%
Operating Temperature
-20°C ~ 50°C
Features
Compliant with the IEEE802.3af Standard
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
993-1088
Power-up Sequence:
Detection Sequence:
Fault Sequence:
Upon power-up, all 3 LEDs will light for 2 seconds, as part of the self-test for the internal
microprocessor software. After the end of the 2 seconds, the "ON" LED will illuminate green,
signifying that the DC output voltage is available for powering a compliant load (to the 802.3at PoE
standards).
Once a compliant load is attached to the output RJ45 connector, the green "CONNECT" LED will
illuminate. Should the load is classified as Class 4 PD, the green “PoEPLUS” LED will illuminate.
Otherwise, “PoEPLUS” LED will stay off.
Should the load be non-compliant then the LEDs will blink a code signifying the cause for non-
detection.
Detection Failure Codes:
1. Incorrect resistive signature – The green “CONNECT” and green “PoEPLUS” LEDs will blink 3
2. Incorrect capacitive signature – The green “ON” LED will blink 3 times.
3. Incorrect Voffset – The green “CONNECT” and green “ON” LEDs will blink 3 times.
4. Unstable current measurement – The green “CONNECT” LED will blink 3 times
5. Low voltage sensed during detection (overload) – The green “PoE PLUS” LED will blink 3 times
After the LEDs blink 3 times the PSE will continue to try to detect a valid load. Therefore, until the
correct load is applied, the LEDs will continue to blink. If there is an open circuit connected to the
output RJ45 then the LEDs will not blink but the PSE will continue to try to detect a valid load.
Should there be a fault such as an overload or short circuit then all the three LEDs will blink 5 times in
2 seconds, and then go off as the power supply tries to re-detect a valid load. If there is a problem in
detecting, the LED will indicate what is wrong with the load as per the codes in the section above.
times.
Description of LED Functions for Gigabit Power Injector
Gigabit Power Injector Block Diagram

Related parts for POE36U-1AT