XR17V358IB176-F Exar Corporation, XR17V358IB176-F Datasheet - Page 38

IC UART PCIE OCTAL 176FPBGA

XR17V358IB176-F

Manufacturer Part Number
XR17V358IB176-F
Description
IC UART PCIE OCTAL 176FPBGA
Manufacturer
Exar Corporation
Datasheet

Specifications of XR17V358IB176-F

Number Of Channels
1, UART
Package / Case
176-LFBGA
Features
*
Fifo's
256 Byte
Protocol
RS485
Voltage - Supply
1.2V, 3.3V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
25 Mbps
Supply Current
120 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
No. Of Channels
8
Uart Features
Tx/Rx FIFO Counters
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
BGA
No. Of Pins
176
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
1016-1296 - EVAL BOARD FOR XR17V358-E81016-1295 - EVAL BOARD FOR XR17V358-E41016-1293 - EVAL BOARD FOR XR17V358
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1016-1294

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR17V358IB176-F
Manufacturer:
EXAR
Quantity:
1 700
Part Number:
XR17V358IB176-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XR17V358IB176-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR17V358
HIGH PERFORMANCE OCTAL PCI EXPRESS UART
REV. 1.0.2
3.2
Automatic Hardware (RTS/CTS or DTR/DSR) Flow Control Operation
Automatic hardware or RTS/DTR and CTS/DSR flow control is used to prevent data overrun to the local
receiver FIFO and remote receiver FIFO. The RTS#/DTR# output pin is used to request remote unit to
suspend/restart data transmission while the CTS#/DSR# input pin is monitored to suspend/restart local
transmitter. The auto RTS/DTR and auto CTS/DSR flow control features are individually selected to fit specific
application requirement and enabled through EFR bit[7:6] and MCR bit [2] for either RTS/CTS or DTR/DSR
control signals. The auto RTS/DTR function must be started by asserting RTS/DTR# output pin (MCR bit [0] or
bit [1] to logic 1) after it is enabled.
Figure 10
below explains how it works.
Two interrupts associated with RTS/DTR and CTS/DSR flow control have been added to give indication when
RTS/DTR# pin or CTS/DSR# pin is de-asserted during operation. The RTS/DTR and CTS/DSR interrupts must
be first enabled by EFR bit [4], and then enabled individually by IER bits [7:6], and chosen with MCR bit [2].
Automatic hardware flow control is selected by setting bits [7 (CTS): 6 (RTS)] of the EFR register to logic 1. If
CTS# pin transitions from LOW to HIGH indicating a flow control request, ISR bit [5] will be set to logic 1, (if
enabled via IER bit [7:6]), and the UART will suspend TX transmissions as soon as the stop bit of the character
in process is shifted out. Transmission is resumed after the CTS# input returns to LOW, indicating more data
may be sent.
38