065074-0002 ITT Cannon, 065074-0002 Datasheet - Page 28

no-image

065074-0002

Manufacturer Part Number
065074-0002
Description
PLUG STR 12-3POS 16AWG SOCKET
Manufacturer
ITT Cannon
Series
KPSEr
Datasheet

Specifications of 065074-0002

Connector Type
Plug, Female Sockets
Number Of Positions
3
Shell Size - Insert
12-3
Mounting Type
Free Hanging (In-Line)
Termination
Crimp
Fastening Type
Bayonet Lock
Orientation
Keyed
Ingress Protection
IP67 - Dust Tight, Waterproof
Shell Material, Finish
Aluminum, Olive Drab Cadmium Plated
Features
Strain Relief
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Shell Size, Military
-
Other names
1003-1105
KPSE06F123S
KPT/KPSE
Contact
size
20
16
12
14A4 Coax
Crimping contacts
1. Strip wires according to the table above taking care
not to cut or nick strands.
4. Release crimped contact and wire from tool. Be
certain the wire is visible thru inspection hole in contact.
7. Beginning from center cavity and working outwards,
insert wired contacts into rear of connector by hand
until the front of the contact shoulder is no more than
1/8" from the grommet. Holding the connector securely,
position tool behind contact. Push tool straight into
contact cavity until contact snaps into position. A light
pull on wire will assure that contact is locked securely.
Repeat for remaining contacts.
Contact extraction
10. Slide hardware back over wire bundle. Using pro-
per extraction tool or extraction end of proper insertion/
extraction tool, proceed as follows:
28
Cable size
mm
0,93-0,21 (20-24)
1,91-0,60 (16-20)
3,18-1,91 (12-14)
RG179B/u
2
(AWG)
Strip
insulation
5,0 mm
6,5 mm
6,5 mm
2. Insert stripped wire into contact crimp pot. Wire must
be visible thru inspection hole.
Contact insertion
5. Remove hardware from plug and receptacle. Slide
hardware over wire bundle in proper order for re-
assembly.
8. Use wire hole fillers or grommet sealing plugs to fill
any empty cavities and assemble hardware to rear of
plug or receptacle.
11. Use the proper extraction tool. There are two lines
on the clip sleeve which are vital to the contact rem-
oval process. The first index line is used for removing
3. Using correct crimp tool and locator, cycle the tool
once to be sure the indentors are open. Insert contact
and wire into locator. Squeeze tool handles firmly and
completely to insure a proper crimp. The tool will not
release unless the crimp indentors in the tool head
have been fully actuated.
6. Use the proper contact insertion tool, and slide the
tool over the terminal end of the contact. The size 16
contact lies in the tool and the tool tip butts against the
contact shoulder. The rear, or insulation support, of the
size 20 contact butts against an internal shoulder in
the tool tip.
Completion
9. Check face of plug or receptacle for proper contact
installation.
pin contacts while the second index line is for removing
socket contacts. Carefully place the tool tip over the
contact to be extracted until the tool tip touches the
insulator face. Carefully rotate the tool until the index
line is slightly below the insulator face. Keep an even
pressure against tool body; push plunger forward with
thumb and index finger; and push the contact out
through the clip. Carefully remove extraction tool from
connector. Pull the wire by hand to complete the rem-
oval of the contact.
Miniature circular connectors
Please ask for our detailed
Assembly Instructions
Assembly Instruction

Related parts for 065074-0002