E3X-NM41 Omron, E3X-NM41 Datasheet - Page 13

QUAD AUTOTUNE PNP RMT TCH

E3X-NM41

Manufacturer Part Number
E3X-NM41
Description
QUAD AUTOTUNE PNP RMT TCH
Manufacturer
Omron
Series
E3X-Nr
Type
Fiber Optic Sensorr
Datasheets

Specifications of E3X-NM41

Output Type
PNP
Amplifier Type
Four Channel
Voltage - Supply
12 V ~ 24 V
Current - Supply
150mA
Mounting Type
DIN Rail
Length/height, External
33mm
Response Time
1ms
Sensor Input
Fiber Optic
External Width
32.2mm
External Depth
59mm
Operating Temperature Min
-25°C
Operating Temperature Max
55°C
Output Current Max
100mA
Rohs Compliant
Yes
Fiber Optic Sensor Type
Fiber Optic Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNM41

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NM41
Manufacturer:
EVERLIGHT
Quantity:
20 390
Precautions
J APPLICATIONS
The E32-V Vacuum Fiber Unit is used to detect a variety of
objects located in high-vacuum chambers heated up to 120°C
(some chambers operate at a maximum temperature of 200°C).
J CLEANING
Although Flanges, Vacuum Fibers, and Lens Units are cleaned
before shipping, clean them with alcohol before use in
high-vacuum chambers to make sure there is no foreign matter
on them.
J ORGANIC SOLVENTS
Keep organic solvents away from the E32-V Vacuum Sensor.
J EXCESSIVE FORCE
The E32-V Vacuum Fiber Unit can resist a maximum force of
29.4 N (3 kgf). Do not impose extreme force, such as pulling
force or pressure, on the E32-V Fibers.
E32-V
J FOR CONDITIONS OR ENVIRONMENTS
Consult your OMRON representative before attempting an
application for: conditions or environments not specified in
instruction manuals, and applications insuring safety, including
nuclear reactor control, train facilities, aviation facilities,
motorized vehicles, furnaces, medical equipment, amusement
equipment, and safety equipment.
Note:
NOT SPECIFIED FOR THIS PRODUCT
You must allow a sufficient margin between ratings and re-
quired performance in addition to providing appropriate
fail-safe measures and other safety measures when using
the E32-V in applications such as mentioned above.
E32-V
13