E3X-DA51-N Omron, E3X-DA51-N Datasheet - Page 16

PREWIRED A/D PNP FO AMP

E3X-DA51-N

Manufacturer Part Number
E3X-DA51-N
Description
PREWIRED A/D PNP FO AMP
Manufacturer
Omron
Series
E3X-DA-Nr
Type
Photoelectric Sensorr
Datasheets

Specifications of E3X-DA51-N

Output Type
PNP
Amplifier Type
Monitor Output
Voltage - Supply
12 V ~ 24 V
Current - Supply
40mA
Mounting Type
*
Sensor Output
PNP
Supply Voltage Min
12V
Sensor Input
Fiber Optic
Supply Voltage Max
24V
Fiber Optic Sensor Type
Photoelectric Sensor
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XDA51N
Precautions
Amplifier units
Design
Power ON
The sensor is ready to sense an object within 200 ms after turn-
ing the power ON. If the load and sensor are connected to differ-
ent power supplies, always turn on the sensor power first.
Mounting
Connection/removing of amplifier units
(Connection)
1. Install the units one by one to the DIN rail.
2. Slide one unit toward the other, match the clips at the front
(Removing)
Slide one unit away from the other and remove them one by
one. (Do not remove the connected units together from the
DIN rail.)
Fitting of Mobile Console head
When fitting the Mobile Console head, a 20 mm or more clear-
ance is needed on the left side.
Use of Mobile Console
For the twin output type (E3X-DA##TW), up to 16 channels
(eight E3X-DA##TW units) can be set from the Mobile Con-
sole E3X-MC11. (Note that the operation mode and area de-
tection cannot be set.)
A-434
Note:1 .When the amplifier units are connected to each other, the
ends, and then bring them together until they "click".
2 .Before connecting or removing the units, always switch
operable ambient temperature changes depending on the
number of connected amplifier units. Check "Ratings/Per-
formance".
power off.
Clip
Correct Use
20mm
Click into
place
Adjustment
Mutual interference prevention function
The digital display value may vary due to the light from the
other sensor. In that case, low the sensitivity (raise the thresh-
old) to stabilize detection.
EEPROM Write Error
If a write error occurs (operation indicator starts flashing) due
to power-off, static electricity or other noise in the teaching
mode, perform teaching again.
Optical communication
When connecting the amplifier units, assemble them in close
contact. During operation, do not slide or dismantle the ampli-
fier units.
Hysteresis adjustment
The Mobile Console allows hysteresis adjustment, but note
that the unit may not operate properly if the hysteresis setting
is lower than the factory value.
Advanced Photoelectric Sensors