Specifications of E3X-NA6

Amplifier Type
Wire Saving
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
35mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNA6
E3XNA6Q
E3X-NA
Nomenclature
I
Lock Button
I
Indicators
In addition to an operation indicator (orange), the E3X-NA also has
incident level indicators (4 green and 1 red). Use these indicators for
optical axis adjustments and maintenance.
Note:
4
Status of indicators
(in L/ON mode)
Operation indicator Incident level indicators
Amplifier Units
LED Bar Display
Operation Indicator
The indicator farthest to the right will be lit even if the incident
level is 0.
Incident level Indicators
Sensitivity Indicator
Not lit
8-Turn Sensitivity Adjuster
Lit
(See note.)
Timer Switch
OFF: Timer function is OFF.
ON: Timer function is ON.
Operation
indicator
(in L/ON
mode)
Not lit
Not lit
Not lit or lit
Lit
Lit
Operation Mode Selector
Use to switch between
Light ON and Dark ON modes.
Incident level
Approx.
80% max. of
operating level
Approx. 80%
to 90% of
operating level
Approx. 90%
to 110% of
operating level
Approx. 110%
to 120% of
operating level
Approx.
120% min. of
operating level