PR01000102009JR500 Vishay, PR01000102009JR500 Datasheet - Page 9

RES 20 OHM METAL FILM 1W 5%

PR01000102009JR500

Manufacturer Part Number
PR01000102009JR500
Description
RES 20 OHM METAL FILM 1W 5%
Manufacturer
Vishay
Series
PR01r

Specifications of PR01000102009JR500

Resistance
20 Ohms
Power Rating
1 Watt
Voltage Rating
350 Volts
Temperature Coefficient
±250ppm/°C
Features
Flame Retardant Coating
Power (watts)
1W
Size / Dimension
0.098" Dia x 0.256" L (2.50mm x 6.50mm)
Tolerance
±5%
Resistance In Ohms
20.0
Lead Style
Through Hole
Composition
Metal Film
Case
Axial
Termination Style
Axial
Operating Temperature Range
- 55 C to + 175 C
Dimensions
2.5 mm Dia. x 6.5 mm L
Package / Case
0207
Resistance Tolerance
± 5%
Resistor Element Material
Metal Film
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Height
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
2306 197 23209::230619723209::5073NW20R00J12AFXBC::5073NW20R00JAFX::BC20W-1TR
PR01/02/03
Vishay BCcomponents
Ø 0.6 mm Cu-leads
Minimum distance from resistor body to PCB = 1 mm
Application Information
www.vishay.com
118
PR01 Temperature rise (ΔT) at the lead end (soldering point) as a
conditions; the data may deviate according to the applications.
conditions; the data may deviate according to the applications.
This graph is based on measured data under constant voltage
This graph is based on measured data under constant voltage
function of dissipated power at various lead lengths after mounting.
PR02 Time to interruption as a function of overload power
PR03 Time to interruption as a function of overload power
(K)
∆ T
(s)
(s)
10
10
10
10
t
t
100
10
10
-1
1
-1
1
80
60
40
20
2
2
0
0
0
0
for range: 0.68 R ≤ R
for range: 5 R ≤ R
20
50
40
0.4
100
60
150
n
For technical questions, contact:
n
< 68 R
80
0.8
≤ 560 R
P
P
overload
overload
Power Metal Film Leaded Resistors
200
P (W)
100
15 mm
25 mm
20 mm
(W)
(W)
120
250
1.2
filmresistorsleaded@vishay.com
Interruption Characteristics
Ø 0.6 mm Cu-leads
Ø 0.6 mm FeCu-leads
conditions; the data may deviate according to the applications.
This graph is based on measured data under constant voltage
PR02 Time to interruption as a function of overload power
PR01 Hot-spot temperature rise (ΔT) as a function
PR01 Hot-spot temperature rise (ΔT) as a function
∆ T
(K)
∆ T
(K)
10
(s)
10
t
200
160
120
10
200
160
120
-1
1
80
40
80
40
2
0
0
0
0
0
for range: 68 R ≤ R
20
of dissipated power.
of dissipated power.
40
0.4
0.4
60
n
80
≤ 560 R
0.8
Document Number: 28729
0.8
P
overload
100
P (W)
P (W)
Revision: 14-Oct-09
(W)
120
1.2
1.2

Related parts for PR01000102009JR500