S20K11 EPCOS Inc, S20K11 Datasheet - Page 18
S20K11
Manufacturer Part Number
S20K11
Description
VARISTOR 11VRMS 20MM RADIAL
Manufacturer
EPCOS Inc
Series
StandarDr
Datasheet
1.S05K140.pdf
(36 pages)
Specifications of S20K11
Varistor Voltage
18V
Current-surge
2kA
Number Of Circuits
1
Maximum Ac Volts
11VAC
Maximum Dc Volts
14VDC
Energy
10J
Package / Case
Disc 20mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
B72220S 110K101
B72220S0110K101
B72220S110K101
B72220S0110K101
B72220S110K101
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Reliability data
Test
Varistor voltage
Clamping voltage
Max. AC operating voltage
Surge current derating,
8/20 µs
Surge current derating,
2 ms
Electric strength
Please read Cautions and warnings and
Important notes at the end of this document.
Leaded varistors
StandarD series
Test methods/conditions
The voltage between two terminals with
the specified measuring current applied
is called V
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
CECC 42 000, test 4.20
1000 h at UCT
After having continuously applied
the maximum allowable voltage at UCT
±2 °C for 1000 h, the specimen shall be
stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of V
measured.
CECC 42 000, test C 2.1
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses at
20 µs
CECC 42 000, test C 2.1
100 surge currents (2 ms), unipolar,
interval 120 s, amplitude corresponding
to derating curve for 100 impulses at
2 ms
CECC 42 000, test 4.7
Metal balls method, 2500 V
The varistor is placed in a container
holding 1.6 ±0.2 mm diameter metal
balls such that only the terminations of
the varistor are protruding.
The specified voltage shall be applied
between both terminals of the speci-
men connected together and the elec-
trode inserted between the metal balls.
v
(1 mA
DC
18
@ 0.2 … 2 s).
11/07
RMS
v
shall be
, 60 s
Requirement
To meet the specified value.
To meet the specified value.
|
|
(measured in direction
of surge current)
No visible damage
|
(measured in direction
of surge current)
No visible damage
No breakdown
∆V/V (1 mA)
∆V/V (1 mA)
∆V/V (1 mA)
|
|
|
≤10%
≤10%
≤10%