P0080SCMC Littelfuse / Teccor Sidactor(R) Product, P0080SCMC Datasheet - Page 156

no-image

P0080SCMC

Manufacturer Part Number
P0080SCMC
Description
SIDACTOR MC BI 6V 400A DO-214AA
Manufacturer
Littelfuse / Teccor Sidactor(R) Product
Series
SIDACtor® SC(MC)r
Datasheet

Specifications of P0080SCMC

Voltage - Breakover
25V
Voltage - Off State
6V
Voltage - On State
5V
Current - Peak Pulse (8 X 20µs)
400A
Current - Peak Pulse (10 X 1000µs)
100A
Current - Hold (ih)
50mA
Number Of Elements
1
Capacitance
75pF
Package / Case
DO-214AA, SMB
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P0080SCMC
Manufacturer:
Littelfuse
Quantity:
45 000
Part Number:
P0080SCMCL
Manufacturer:
Littelfu
Quantity:
150 000
Part Number:
P0080SCMCLRP
Manufacturer:
Littelfu
Quantity:
73 500
Part Number:
P0080SCMCLRP
Manufacturer:
LITTELFUSE/力特
Quantity:
20 000
Part Number:
P0080SCMCRP
Manufacturer:
Littelfu
Quantity:
30 000
UL 497C
UL 497C
http://www.teccor.com
+1 972-580-7777
UL 497C requirements cover protectors for use on coaxial cable circuits. This standard
covers construction and performance requirements.
UL 497C Construction and Performance Requirements
The “Construction” section covers the following requirements:
• General
• Corrosion Protection
• Field-wiring Connections
• Components
• Spacing
• Enclosures
The “Performance” section covers the following requirements:
• General
• I
• Abnormal Sustained Current
• Component Temperature Test
• Breakdown Voltage Measurement
• Impulse Spark-over Voltage Measurement
• Limited Short-circuit Test
• High Current Ground Path Test
• Cable Shield Fuse Test
• Endurance Conditioning Test
• Induced Low Current Test
• Distortion Test
• Flame Test
• Impact Test (Polymeric Enclosures)
• Jarring Test
• Water Spray Test
• Leakage Current Test
• Dielectric Voltage-withstand Test
• Ultraviolet Light and Water Exposure
• Tensile Strength and Elongation Tests
• Air Oven Aging
• Ozone Exposure
Performance Requirements Specific to SIDACtor Devices
1. Strike Voltage Breakdown Test — Protectors are required to break down within ±25% of
2. Endurance Conditioning — Protectors are subjected to 500 impulse cycles. Each cycle is
the manufacturer’s specified breakdown range but no higher than 750 V at £ 2 kV/s rise
time.
a 1000 V peak, 10 A, 10x1000 µs pulse. Pulses are applied in one polarity at 10-second
intervals and then repeated in the opposite polarity. Then, 100 cycles of 1000 V peak,
100 A, 10x1000 µs pulse are applied to three new protectors. Finally, two cycles of
2
t Limiting
4 - 32
SIDACtor
®
Data Book and Design Guide
© 2002 Teccor Electronics

Related parts for P0080SCMC