Page 1
... The MIC5246 offers better than 1% initial accuracy, extremely-low-dropout volt- age (typically 150mV at 150mA) and constant ground current (typically 85 A)over load . The MIC5246 features an error flag that indicates an output fault condition such as overcurrent, thermal shutdown and dropout. The MIC5246 provides a very low noise output, ideal for RF applications where quiet voltage sources are required ...
Page 2
... GND LTxx 4 5 FLG OUT MIC5246-x.xBM5 Pin Function Supply Input Ground Enable/Shutdown (Input): CMOS compatible input. Logic high = enable; logic low = shutdown. Do not leave open. Error Flag (Output): Open-drain output. Active low indicates an output undervoltage condition. Regulator Output Operating Ratings (Note 1) ...
Page 3
... OFF) OUT I = 100 A, fault condition L flag off FLG 3 T +125 C; unless noted. J Min Typical Max –1 1 –2 2 –0 100 150 150 200 250 0 150 85 150 50 160 300 0.8 0.4 1.6 1 0.01 0.01 500 150 0.02 0.4 0.01 Micrel Units % % %/ MIC5246 ...
Page 4
... LOAD 0 FREQUENCY (Hz) Ground Pin Current 100 150mA LOAD 0 -40 - 110 140 TEMPERATURE ( C) Dropout Characteristics 4 100 A 3 150mA VOLTAGE IN (V) MIC5246 Power Supply Rejection Ratio 50mA LOAD 0 FREQUENCY (Hz) Ground Current vs. Output Current 100 1000 OUTPUT CURRENT (mA) Ground Pin Current 100 100 A LOAD ...
Page 5
... MIC5246 Typical Characteristics Short Circuit Current vs. Temperature 400 300 200 100 0 -40 -10 20 TEMPERATURE ( C) June 2000 3.40 3.36 3.32 3.28 3. OUT 3. 110 140 -40 5 Output Voltage vs. Temperature - 110 140 TEMPERATURE ( C) Micrel MIC5246 ...
Page 6
... MIC5246 Block Diagrams IN EN Reference Voltage Thermal Sensor Under- voltage Lockout Overcurrent Dropout Detection MIC5246 Startup/ Quickstart Shutdown Control FAULT Error Current Amplifier Amplifier ACTIVE SHUTDOWN Out of Regulation Detection 6 PULL UP OUT PULL DOWN FLG GND June 2000 Micrel ...
Page 7
... A). Active Shutdown The MIC5246 also features an active shutdown clamp, which is an N-channel MOSFET that turns on when the device is disabled. This allows the output capacitor and load to dis- charge, de-energizing the load. ...
Page 8
... D(max) D conditions that are critical to the application will give the maximum operating conditions for the regulator circuit. For example, when operating the MIC5246-3.0BM5 with a minimum footprint layout, the maximum input voltage for a set output current can be determined as follows: 125 ...
Page 9
... REF 3.02 (0.119) 2.80 (0.110) 0.50 (0.020) 0.35 (0.014) June 2000 1.75 (0.069) 3.00 (0.118) 1.50 (0.059) 2.60 (0.102) DIMENSIONS: MM (INCH) 1.30 (0.051) 0.90 (0.035 0.15 (0.006) 0.60 (0.024) 0.00 (0.000) 0.10 (0.004) SOT-23-5 (M) 9 Micrel 0.20 (0.008) 0.09 (0.004) MIC5246 ...
Page 10
... MIC5246 MIC5246 10 Micrel June 2000 ...
Page 11
... MIC5246 June 2000 11 Micrel MIC5246 ...
Page 12
... This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc. MIC5246 + 1 (408) 944-0970 http://www ...