MAX701EPA+ Maxim Integrated Products, MAX701EPA+ Datasheet - Page 2

IC PWR-SUP MONITOR W/RESET 8-DIP

MAX701EPA+

Manufacturer Part Number
MAX701EPA+
Description
IC PWR-SUP MONITOR W/RESET 8-DIP
Manufacturer
Maxim Integrated Products
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of MAX701EPA+

Number Of Voltages Monitored
1
Output
Push-Pull, Push-Pull
Reset
Active High/Active Low
Reset Timeout
200 ms Minimum
Voltage - Threshold
4.65V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Monitored Voltage
3 V to 15 V
Output Type
Active High, Active Low, Push-Pull
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Supply Voltage (max)
15 V
Supply Voltage (min)
3 V
Supply Current (typ)
200 uA
Maximum Power Dissipation
380 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Undervoltage Threshold
4.5 V
Overvoltage Threshold
4.75 V
Power-up Reset Delay (typ)
500 ms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ABSOLUTE MAXIMUM RATINGS
V
Voltage (with respect to GND) at RESET, RESET,
Operating Temperature Range
Power-Supply Monitor with Reset
ELECTRICAL CHARACTERISTICS
(V
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
2
V
(MAX700 Only)
Min V
Declining Supply
Supply Current
Reset Threshold
Internal Hysteresis
Reset Output Pulse Width
RESET Fall Time
V
MR Input Threshold
MR Pullup Current
MAX700
RESET Output Low
RESET Output High
RESET Output Low
RESET Output High
CC
CC
CC
CC
HYST, CTL, SENSE ............................................-0.3V to V
C Suffix .............................................................0°C to +70°C
E Suffix...........................................................-40°C to +85°C
_______________________________________________________________________________________
......................................................................-0.3V to +15.5V
= +5V, CTL = GND on MAX700, T
Monitor Voltage Range
Pulse Duration Guaranteeing
CC
for Valid Reset Output,
PARAMETER
T
T
T
HYST not connected
MAX700/MAX701 only, C
5V to 4V V
I
I
I
I
I
I
I
I
I
I
SINK
SINK
SOURCE
SOURCE
SOURCE
SINK
SINK
SINK
SOURCE
SOURCE
A
A
A
A
= T
= T
= T
= +25°C, unless otherwise noted.)
= 3.2mA, V
= 1.6mA, V
= 16mA, V
= 1.6mA, V
= 0.4mA, V
MIN
MIN
MIN
= 3.2mA, V
= 1.6mA, V
= 0.5mA, V
= 3.2mA, V
= 1.6mA, V
CC
to T
to T
to T
pulse
MAX
MAX
MAX
CC
CC
CC
CC
CC
, CTL = V
, RESET ≤ 0.4V when sinking 1mA
= 4.25V
= 5V
= 3V
= 3V
= 1.5V
CC
CC
CC
CC
CC
CONDITIONS
CC
= 4.25V
= 3V
= 1.5V
= 5V
= 3V
LOAD
CC
Power-up
Power-down
No reset
Reset
= 100pF
Rate of Rise, V
Power Dissipation, Any Package .....................................380mW
Storage Temperature Range .............................-55°C to +150°C
Lead Temperature (soldering, 10s)..................................+300°C
CC
............................................................100V/µs
V
V
V
V
V
4.50
4.50
MIN
200
100
1.5
0.4
0.4
0.4
0.4
0.4
CC
CC
CC
CC
CC
3
-
-
-
-
-
TYP
4.65
4.62
100
350
200
0.7
30
10
10
-5
1
MAX
4.75
4.75
200
500
-30
0.4
0.4
0.4
0.4
0.4
15
1
UNITS
mV
ms
µA
µA
ns
µs
V
V
V
V
V
V
V
V

Related parts for MAX701EPA+