Specifications of 2026-60-C13

Spark Over Voltage
600V
Tolerance
±20%
Impulse Discharge Current
40kA 8x20µs
Package / Case
Radial - 3 Lead
Mounting Type
Through Hole
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
REV. 04/11
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Switch-Grade Fail-short Device Shorting Curve 2026-XX-XF
2026 Series - 3-Pole Gas Discharge Tube
30.0
20.0
10.0
5.0
1.0
0.5
0.1
1
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT fail-short device, it is imperative that all components associated and
connected to the GDT with failsafe be tested in their respective completely integrated environment
(finished product) to assure desired operation.