M51-A230X EPCOS Inc, M51-A230X Datasheet - Page 2

SURGE ARRESTER 230V GASTUBE 2PIN

M51-A230X

Manufacturer Part Number
M51-A230X
Description
SURGE ARRESTER 230V GASTUBE 2PIN
Manufacturer
EPCOS Inc
Series
M51-A230Xr
Datasheet

Specifications of M51-A230X

Spark Over Voltage
230V
Tolerance
±20%
Impulse Discharge Current
5.0kA 8x20µs
Package / Case
Axial
Mounting Type
Through Hole
Peak Pulse Current
10 KA
Dc Breakover Voltage (nominal)
230 V
Number Of Electrodes
2
Termination Style
Axial
Failsafe Protection Y/n
N
Mounting Style
Through Hole
Technology
Surge Arrester
Suppressor Type
Gas Discharge Tube (GDT)
Dc Breakover Voltage
230V
Impulse Sparkover Voltage
650V
Gdt Case Style
2 Terminal Through Hole
Rohs Compliant
Yes
Sparkover Voltage Dc
230V
Svhc
No SVHC (20-Jun-2011)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
495-2632
B88069X2930C102
M51-A230X
Q2588745

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M51-A230X
Manufacturer:
PANASONIC
Quantity:
82
Part Number:
M51-A230XG
Manufacturer:
EPCOS
0
Electrical specifications
KB AB E / KB AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
DC spark-over voltage
Impulse spark-over voltage
Service life
Insulation resistance at 100 V
Capacitance at 1 MHz
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
Weight
Operation and storage temperature
Climatic category (IEC 60068-1)
Marking, blue negative
1)
2)
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
Surge arrester
2-electrode arrester
Features
At delivery AQL 0.65 level II, DIN ISO 2859
In ionized mode
Very small size
High current rating
Very fast response time
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
10 operations
10 operations
at 100 V/µs
at 1 kV/µs
1 operation
1 operation
1 operation
1) 2)
- for 99 % of measured values
- typical values of distribution
- for 99 % of measured values
- typical values of distribution
50 Hz, 1 s
50 Hz, 0.18 s (9 cycles)
8/20 µs
8/20 µs
10/350 µs
dc
Page 2 of 4
Applications
Branch exchange
Line protection
Subscriber protection
Alarm system
230
± 20
< 550
< 500
< 650
< 600
5
10
5
10
0.5
> 1
< 1
~ 15
~ 0.5
~ 60
~ 1
-40 ... +90
40/ 90/ 21
230
YY
O
- Nominal voltage
- Year of production
- Non radioactive
230 YY O
B88069X2930C102
Issue 04 / 2007-04-18
M51-A230X
V
%
V
V
V
V
A
A
kA
kA
kA
pF
V
A
V
g
°C