MAX6371KA+T Maxim Integrated Products, MAX6371KA+T Datasheet - Page 6

IC TIMER WATCHDOG SOT23-8

MAX6371KA+T

Manufacturer Part Number
MAX6371KA+T
Description
IC TIMER WATCHDOG SOT23-8
Manufacturer
Maxim Integrated Products
Type
Watchdog Circuitr
Datasheet

Specifications of MAX6371KA+T

Number Of Voltages Monitored
1
Output
Push-Pull, Totem Pole
Reset
Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
Adjustable/Selectable
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
SOT-23-8
Output Type
Active Low, Open Drain
Manual Reset
Not Resettable
Watchdog
Watchdog
Battery Backup Switching
No Backup
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.5 V
Supply Current (typ)
8 uA
Maximum Power Dissipation
700 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
MAX6371KA+T
MAX6371KA+TTR
Pin-Selectable Watchdog Timers
• Watchdog Timeout Period:
Figure 1. Functional Diagram
Figure 2. Watchdog Timing
6
Normal operating watchdog timeout period after the
initial startup delay.
A watchdog output pulse is asserted if a valid watch-
dog input transition is not received before the timeout
period elapses.
Eight pin-selectable timeout period options for each
device, from 30µs to 60s.
Pin-selectable watchdog timer disable feature.
_______________________________________________________________________________________
SET 2
SET 1
SET 0
A
B
C
D
E
F
G
WDO
V
WDI
CC
TRANSITIONS ON WDI IGNORED DURING SETUP DELAY.
TRANSITION(S) ON WDI IGNORED DURING STARTUP DELAY PERIOD.
WATCHDOG TIMER STARTS AFTER STARTUP DELAY AND WDO IS DEASSERTED.
TRANSITION OCCURS BEFORE WATCHDOG TIMEOUT PERIOD. WATCHDOG
TIMER CLEARS AND STARTS TIMER AGAIN.
WATCHDOG TIMES OUT, WDO ASSERTS.
TRANSITIONS ON WDI IGNORED WHEN WDO ASSERTED.
WATCHDOG TIMER STARTS AFTER WDO DEASSERTS.
MAX6369–MAX6374
A
t
SETUP
CONTROL
A
LOGIC
B
t
DELAY
V
CC
ENABLE
SET WATCHDOG TIMEOUT
SET STARTUP DELAY
C
TIMER CIRCUITRY
TRANSITION
WATCHDOG
DETECTOR
CLEAR
t
GND
WDI
WD
D
• Watchdog Output/Timing Options:
Each device has a watchdog startup delay that is initi-
ated when the supervisor is first powered or after the
user modifies any of the logic control set inputs. The
watchdog timer does not begin to count down until the
Open drain, active low with 100ms minimum watch-
dog output pulse (MAX6369/MAX6371/MAX6373).
Push-pull, active low with 1ms minimum watchdog
output pulse (MAX6370/MAX6372/MAX6374).
t
WD
OUT
EN
E F
t
WDO
OUTPUT
G
t
WD
WDO
E

Related parts for MAX6371KA+T