Page 1
... In a typical implementation, motor currents flow through an external resistor and the resulting analog voltage drop is sensed by the HCPL-7800A. A differential output voltage is created on the other side of the HCPL-7800A optical isolation barrier. This differential output voltage is proportional to the motor current and can be converted to a single-ended signal by using an op-amp ...
Page 2
Isolation Amplifier Fully Differential Circuit Topology Options available are: 300 = Surface Mount Option 500 = Tape and Reel Packaging Option Applications Motor Phase and Rail Current Sensing Inverter Current Sensing Switched Mode Power Supply Signal Isolation General Purpose Current ...
Page 3
... HCPL-7800(A). A differential output voltage is created on the other side of the HCPL-7800(A) optical isolation barrier. This differential output voltage is pro- portional to the motor current and can be converted to a single-ended signal by using an op-amp as shown in the recommended application circuit ...
Page 4
... MAX. 3.56 ± 0.13 (0.140 ± 0.005) 1.080 ± 0.320 (0.043 ± 0.013) Note: Initial or continued variation in the color of the HCPL-7800(A)’s white mold compound is normal and does not affect device performance or reliability. Surface Gull Package Mount Wing ...
Page 5
Gull Wing Surface Mount Option 300 9.80 ± 0.25 (0.386 ± 0.010 7800 YYWW 1 2 1.19 (0.047) MAX. 1.080 ± 0.320 (0.043 ± 0.013) 2.54 (0.100) BSC DIMENSIONS IN MILLIMETERS (INCHES). TOLERANCES (UNLESS OTHERWISE SPECIFIED): NOTE: ...
Page 6
... Regulatory Information The HCPL-7800(A) has been approved by the following organizations: IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2): 2003-01. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Description Installation classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage 300 Vrms ...
Page 7
Insulation and Safety Related Specifications Parameter Minimum External Air Gap (Clearance) Minimum External Tracking (Creepage) Minimum Internal Plastic Gap (Internal Clearance) Tracking Resistance (Comparative Tracking Index) Isolation Group Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Supply Voltage Steady-State Input ...
Page 8
... Min./Max. specifications are within the Recommended Operating Conditions. DD2 A Parameter Symbol Input Offset Voltage V OS Magnitude of Input Offset |DV /DT OS Change vs. Temperature Gain (HCPL-7800A Gain (HCPL-7800 Magnitude of V |DG/DT OUT Gain Change vs.Temperature V 200 mV Nonlinearity NL OUT 200 Magnitude of V |dNL OUT 200 200 mV Nonlinearity Change vs ...
Page 9
AC Electrical Specifications Unless otherwise noted, all typicals and figures are at the nominal operating conditions and T = 25°C; all Min./Max. specifications are within the Recommended Operating Conditions. DD2 A Parameter Symbol Min. ...