ATTINY11-6SU Atmel, ATTINY11-6SU Datasheet - Page 27

IC MCU AVR 1K FLASH 6MHZ 8-SOIC

ATTINY11-6SU

Manufacturer Part Number
ATTINY11-6SU
Description
IC MCU AVR 1K FLASH 6MHZ 8-SOIC
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY11-6SU

Core Processor
AVR
Core Size
8-Bit
Speed
6MHz
Peripherals
WDT
Number Of I /o
6
Program Memory Size
1KB (512 x 16)
Program Memory Type
FLASH
Voltage - Supply (vcc/vdd)
4 V ~ 5.5 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
8-SOIC (5.3mm Width), 8-SOP, 8-SOEIAJ
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Ram Size
-
Data Converters
-
Connectivity
-
External Reset
Brown-out Detection
(ATtiny12)
1006F–AVR–06/07
An external reset is generated by a low level on the RESET pin. Reset pulses longer
than 50 ns will generate a reset, even if the clock is not running. Shorter pulses are not
guaranteed to generate a reset. When the applied signal reaches the Reset Threshold
Voltage – V
period (t
Figure 19. External Reset during Operation
ATtiny12 has an on-chip brown-out detection (BOD) circuit for monitoring the V
during the operation. The BOD circuit can be enabled/disabled by the fuse BODEN.
When BODEN is enabled (BODEN programmed), and V
level, the brown-out reset is immediately activated. When V
ger level, the brown-out reset is deactivated after a delay. The delay is defined by the
user in the same way as the delay of POR signal, in Table 14. The trigger level for the
BOD can be selected by the fuse BODLEVEL to be 1.8V (BODLEVEL unprogrammed),
or 2.7V (BODLEVEL programmed). The trigger level has a hysteresis of 50 mV to
ensure spike-free brown-out detection.
The BOD circuit will only detect a drop in V
for longer than 7 µs for trigger level 2.7V, 24 µs for trigger level 1.8V (typical values).
Figure 20. Brown-out Reset during Operation (ATtiny12)
Note:
INTERNAL
TIME-OUT
INTERNAL
TIME-OUT
RESET
RESET
RESET
RESET
V
CC
V
The hysteresis on V
TOUT
CC
RST
) has expired.
– on its positive edge, the delay timer starts the MCU after the Time-out
V
RST
BOT
: V
BOT +
V
BOT-
= V
t
BOT
TOUT
+ 25 mV, V
CC
if the voltage stays below the trigger level
BOT-
= V
CC
BOT
decreases below the trigger
CC
V
t
TOUT
- 25 mV.
BOT+
increases above the trig-
ATtiny11/12
CC
level
27

Related parts for ATTINY11-6SU