M30262F8GP#U9 Renesas Electronics America, M30262F8GP#U9 Datasheet - Page 138

IC M16C/TINY MCU FLASH 48LQFP

M30262F8GP#U9

Manufacturer Part Number
M30262F8GP#U9
Description
IC M16C/TINY MCU FLASH 48LQFP
Manufacturer
Renesas Electronics America
Series
M16C™ M16C/Tiny/26r
Datasheets

Specifications of M30262F8GP#U9

Core Processor
M16C/60
Core Size
16-Bit
Speed
20MHz
Connectivity
I²C, IEBus, SIO, UART/USART
Peripherals
DMA, WDT
Number Of I /o
38
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
48-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M30262F8GP#U9M30262F8GP
Manufacturer:
NA
Quantity:
20 000
Company:
Part Number:
M30262F8GP#U9M30262F8GP#D3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U9M30262F8GP#D5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U9M30262F8GP#U3
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M30262F8GP#U9M30262F8GP#U5
Manufacturer:
Renesas Electronics America
Quantity:
10 000
[ Function ]
SMOVB
[ Syntax ]
[ Operation ]
[ Flag Change ]
[ Description Example ]
[ Related Instructions ]
Chapter 3
Change
SMOVB.size
Flag
• This instruction transfers string in successively address decrementing direction from the source ad-
• Set the 4 high-order bits of the source address in R1H, the 16 low-order bits of the source address in
• The A0 or A1 when the instruction is completed contains the next address of the last-read data.
• If an interrupt request is received during instruction execution, the interrupt is acknowledged after one
SMOVB.B
When size specifier (.size) is (.B)
dress indicated by 20 bits to the destination address indicated by 16 bits.
A0, the destination address in A1, and the transfer count in R3.
data transfer is completed.
*1
*2
U
Repeat
Until
*1
If you set a value 0 in R3, this instruction is ingored.
If A0 underflows, the content of R1H is decremented by 1.
I
Functions
M(A1)
A0
A1
R3
O
*2
B
S
SMOVF,SSTR
M(2
A0
A1
R3
R3 = 0
Z
16
D
R1H + A0)
1
1
1
String MOVe Backward
Transfer string backward
C
B , W
120
When size specifier (.size) is (.W)
Repeat
Until
[ Instruction Code/Number of Cycles ]
M(A1)
A0
A1
R3
*2
M(2
A0
A1
R3
R3 = 0
16
SMOVB
R1H + A0)
2
2
1
3.2
Page=
Functions
232

Related parts for M30262F8GP#U9