C8051T617-GM Silicon Laboratories Inc, C8051T617-GM Datasheet - Page 138

IC 8051 MCU 16K BYTE-PROG 24-QFN

C8051T617-GM

Manufacturer Part Number
C8051T617-GM
Description
IC 8051 MCU 16K BYTE-PROG 24-QFN
Manufacturer
Silicon Laboratories Inc
Series
C8051T61xr
Datasheets

Specifications of C8051T617-GM

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
21
Program Memory Size
16KB (16K x 8)
Program Memory Type
OTP
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
1.8 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
24-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
Other names
336-1438-5
C8051T610/1/2/3/4/5/6/7
SFR Definition 22.1. SMB0CF: SMBus Clock/Configuration
SFR Address = 0xC1
138
Name
Reset
1:0 SMBCS[1:0] SMBus Clock Source Selection.
Bit
Type
7
6
5
4
3
2
Bit
EXTHOLD
SMBTOE
SMBFTE
ENSMB
Name
BUSY
ENSMB
INH
R/W
7
0
SMBus Enable.
This bit enables the SMBus interface when set to 1. When enabled, the interface
constantly monitors the SDA and SCL pins.
SMBus Slave Inhibit.
When this bit is set to logic 1, the SMBus does not generate an interrupt when slave
events occur. This effectively removes the SMBus slave from the bus. Master Mode
interrupts are not affected.
SMBus Busy Indicator.
This bit is set to logic 1 by hardware when a transfer is in progress. It is cleared to
logic 0 when a STOP or free-timeout is sensed.
SMBus Setup and Hold Time Extension Enable.
This bit controls the SDA setup and hold times according to Table 22.2.
0: SDA Extended Setup and Hold Times disabled.
1: SDA Extended Setup and Hold Times enabled.
SMBus SCL Timeout Detection Enable.
This bit enables SCL low timeout detection. If set to logic 1, the SMBus forces
Timer 3 to reload while SCL is high and allows Timer 3 to count when SCL goes low.
If Timer 3 is configured to Split Mode, only the High Byte of the timer is held in reload
while SCL is high. Timer 3 should be programmed to generate interrupts at 25 ms,
and the Timer 3 interrupt service routine should reset SMBus communication.
SMBus Free Timeout Detection Enable.
When this bit is set to logic 1, the bus will be considered free if SCL and SDA remain
high for more than 10 SMBus clock source periods.
These two bits select the SMBus clock source, which is used to generate the SMBus
bit rate. The selected device should be configured according to Equation 22.1.
00: Timer 0 Overflow
01: Timer 1 Overflow
10: Timer 2 High Byte Overflow
11: Timer 2 Low Byte Overflow
R/W
INH
6
0
BUSY
R
5
0
EXTHOLD SMBTOE
R/W
Rev 1.0
4
0
Function
R/W
3
0
SMBFTE
R/W
2
0
1
0
SMBCS[1:0]
R/W
0
0