PIC18F258-E/SO Microchip Technology, PIC18F258-E/SO Datasheet - Page 21

IC MCU FLASH 16KX16 CAN 28-SOIC

PIC18F258-E/SO

Manufacturer Part Number
PIC18F258-E/SO
Description
IC MCU FLASH 16KX16 CAN 28-SOIC
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18F258-E/SO

Core Processor
PIC
Core Size
8-Bit
Speed
40MHz
Connectivity
CAN, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, POR, PWM, WDT
Number Of I /o
22
Program Memory Size
32KB (16K x 16)
Program Memory Type
FLASH
Eeprom Size
256 x 8
Ram Size
1.5K x 8
Voltage - Supply (vcc/vdd)
4.2 V ~ 5.5 V
Data Converters
A/D 5x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 125°C
Package / Case
28-SOIC (7.5mm Width)
Processor Series
PIC18F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
1.5 KB
Interface Type
SPI, I2C, USART
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
22
Number Of Timers
4 bit
Operating Supply Voltage
2 V to 5.5 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000, DM163011, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
5 bit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F258-E/SO
Manufacturer:
MIC
Quantity:
20 000
4.2
The verify step involves reading back the code memory
space and comparing against the copy held in the pro-
grammer’s buffer. Memory reads occur a single byte at
a time, so two bytes must be read to compare against
the word in the programmer’s buffer. Refer to
Section 4.1 for implementation details of reading code
memory.
FIGURE 4-2:
 2010 Microchip Technology Inc.
Verify Code Memory and ID
locations
No
Read High Byte
Read Low Byte
Set Pointer = 0
word = expect
code memory
VERIFY CODE MEMORY FLOW
verified?
data?
Does
Start
All
Yes
Yes
No
Failure,
Report
Error
The Table Pointer must be manually set to 200000h
(base address of the ID locations) once the code mem-
ory has been verified. The post-increment feature of
the Table Read 4-bit command may not be used to
increment the Table Pointer beyond 1FFFFFh.
No
Set Pointer = 200000h
PIC18FXX2/XX8
Read High Byte
Read Low Byte
word = expect
ID locations
verified?
data?
Done
Does
All
Yes
Yes
No
DS39576C-page 21
Failure,
Report
Error

Related parts for PIC18F258-E/SO