... The errata listed in Table 1 are found in Zilog’s Z8F640x family products (includes Z8F480x, Z8F320x, Z8F240x, and Z8F160x) without a QUAL topmark and with date codes 0239 and later, where the date code is YYWW (year and week of assembly). When reviewing the following errata, refer to the most recent version of the product specification ...
Page 2
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 1. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 4 UART Overrun Framing Error, Parity Error, Break Detect, and ...
Page 3
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 1. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 6 The TXST bit in the When data is written ...
Page 4
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 1. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 9 SPI operating the SPI devices on ...
Page 5
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 1. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 13 With the SPI With the SPI configured for multi-master ...
Page 6
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 1. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 18 When receiving The IrDA endec is sensitive to external ...
Page 7
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x with QUAL Topmark The errata listed in Table 2 are found in the Z8F640x products with a QUAL topmark and date codes 0239 and later, where ...
Page 8
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 2. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 4 UART Overrun Framing Error, Parity Error, Break Detect, and ...
Page 9
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 2. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 6 Reset is not gener- Reset is not generated when ...
Page 10
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 2. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 10 SPI operating the SPI devices on ...
Page 11
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 2. Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x Errata for Devices with Date Codes 0239 and Later (Continued Summary Description 14 With the SPI With the SPI configured for multi-master ...
Page 12
... YYWW (year and week of assembly). If you have devices with these date codes, you must ® contact Zilog to obtain replacements. When reviewing the following errata, refer to the most recent ver- sion of the product specification. Data contained in this document is Preliminary only. ...
Page 13
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 3. Z8F6403 Errata for Devices with Date Codes 0226 and Earlier (Continued Summary Description 2 First cycle of Pulse- The TIOI bit, which sets the initial state of ...
Page 14
Errata to Z8F640x, Z8F480x, Z8F320x, Z8F240x, Z8F160x (Z8 Encore! Table 3. Z8F6403 Errata for Devices with Date Codes 0226 and Earlier (Continued Summary Description 7 Port H alternate When the alternate function for Port H is enabled, the ...
Page 15
... TECHNOLOGY DESCRIBED HEREIN OR OTHERWISE. The information contained within this document has been verified according to the general principles of electrical and mechanical engineering. Z8, Z8 Encore!, and Z8 Encore! XP are registered trademarks of Zilog, Inc. All other product or service names are the property of their respective owners. ...