B78108S1153K EPCOS Inc, B78108S1153K Datasheet - Page 14

CHOKE RF 15UH 610MA AXIAL

B78108S1153K

Manufacturer Part Number
B78108S1153K
Description
CHOKE RF 15UH 610MA AXIAL
Manufacturer
EPCOS Inc
Series
BCr
Type
Ferrite Corer
Datasheets

Specifications of B78108S1153K

Inductance
15µH
Tolerance
±10%
Current
610mA
Dc Resistance (dcr)
600 mOhm Max
Q @ Freq
60 @ 2.52MHz
Self Resonant Freq
20MHz
Package / Case
Axial
Mounting Type
Through Hole
Frequency - Test
2.52MHz
Material - Core
Ferrite Drum
Applications
General Purpose
Core Material
Ferrite
Dimensions
4 mm Dia. x 9.2 mm L
Test Frequency
2.52 MHz
Maximum Dc Current
610 mAmps
Maximum Dc Resistance
0.6 Ohms
Self Resonant Frequency
610 MHz
Q Minimum
60
Operating Temperature Range
- 55 C to + 125 C
Termination Style
Axial
Inductance Tolerance
± 10%
Dc Resistance Max
0.6ohm
Dc Current Rating
610mA
Q Test Frequency
2.52MHz
Inductor Case Style
Axial Leaded
No. Of Pins
2
Svhc
No SVHC (18-Jun-2010)
Rohs Compliant
Yes
Body Diameter
4mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Current - Saturation
-
Current - Temperature Rise
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
B78108S1153K000
7
7.1
The rated voltage V
component at temperatures between the lower category temperature T
temperature T
7.2
The test voltage V
test duration in the course of final inspection (100% end of line testing). This test may be repeated
once as an incoming goods inspection test.
7.3
The rated current l
the nominal operating conditions.
For components with 1, 2 or 3 lines, the rated current is specified for simultaneous flow of a current
of this value through all lines.
During ac operation, higher thermal loads may be caused due to waveforms which deviate from a
pure sine wave. Where necessary, such cases must be taken into consideration.
7.4
The rated current may be exceeded briefly. Details on permissible currents and load duration can
be obtained upon request.
7.5
Saturation effects (e.g in the ferrite cores used) may occur when high-energy pulses are applied to
the components and these may lead to impaired interference suppression. The maximum permis-
sible voltage-time integral area is used to characterize the pulse handling capability of chokes. For
standard components a range from 1 to 10 mVs can be assumed. More specific data can be ob-
tained upon request.
7.6
At ambient temperatures above the operating temperature stated in the data sheet, the operating
current must be reduced according to the derating curve.
7.7
The rated inductance L
measured at the frequency f
General Technical Information
Electrical characteristics
Rated voltage V
Test voltage V
Rated current I
Overcurrent
Pulse handling capability
Current derating I
Rated inductance L
max
.
T
R
is the ac or dc voltage which may be applied to the component for the specified
is ac or dc current at which the component may be continuously operated under
R
is the maximum ac or dc voltage which can be continuously applied to the
T
R
R
R
is the inductance which has been used to designate the choke, as
op
L
.
R
/ I
R
22
04/00
min
and the upper category

Related parts for B78108S1153K