LB2518T1R5M Taiyo Yuden, LB2518T1R5M Datasheet - Page 12

no-image

LB2518T1R5M

Manufacturer Part Number
LB2518T1R5M
Description
INDUCTOR WOUND 1.5UH 405MA 1007
Manufacturer
Taiyo Yuden
Series
LBr
Datasheets

Specifications of LB2518T1R5M

Inductance
1.5µH
Current
405mA
Tolerance
±20%
Dc Resistance (dcr)
91 mOhm Max
Self Resonant Freq
80MHz
Package / Case
1007 (2518 Metric)
Mounting Type
Surface Mount
Operating Temperature
-25°C ~ 105°C
Frequency - Test
7.96MHz
Applications
General Purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Q @ Freq
-
Current - Saturation
-
Current - Temperature Rise
-
Other names
587-2513-2
LB2518T1R5M

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LB2518T1R5M
Manufacturer:
TAIYO YUDEN
Quantity:
66 000
Part Number:
LB2518T1R5M
Manufacturer:
TAIYO
Quantity:
284 000
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
wound0103_reli_e-01
20.High temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM Series
LEM Series
21.Loading at high temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM, LEM Series
22.Low temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM Series
LEM Series
23.Standard condition
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM, LEM Series
Temperature:85±2℃
Duration:1000 hrs
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
LEM:Recovery
At least 1 hr of recovery under the standard condition after the test, followed by the measurement within 2 hrs.
Temperature:85±2℃
Duration:1000 hrs
Applied current:Rated current
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
Temperature:-40±2℃
Duration:1000 hrs
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
LEM:Recovery
At least 1 hr of recovery under the standard condition after the test, followed by the measurement within 2 hrs.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Inductance change:Within±10%
Inductance change :Within±10%
Q→ R12~4R7:30 min.
Inductance change:Within±10%
Inductance change:Within±10%
Inductance change :Within±10%
Q→ R12~4R7:30 min.
Standard test conditions
Unless specified, Ambient temperature is 20±15℃ and the Relative humidity is 65±
20%. If there is any doubt about the test results, further measurement shall be had
within the following limits:
Inductance value is based on our standard measurement systems.
Ambient Temperature: 20±2℃
Relative humidity: 65±5%
5R6~330:25 min.
390~820:20 min.
101:15 min.
5R6~330:25 min.
390~820:20 min.
101:15 min.
1 1
No significant abnormality in appearance.
No significant abnormality in appearance.
No significant abnormality in appearance.
wound0103_reli-PRP5