CT-1205 CUI Inc, CT-1205 Datasheet - Page 3

BUZZER MAGNETIC 12.8MM 3-8V SMD

CT-1205

Manufacturer Part Number
CT-1205
Description
BUZZER MAGNETIC 12.8MM 3-8V SMD
Manufacturer
CUI Inc
Series
CTr
Type
Magnetic Transducer, External Driver
Datasheet

Specifications of CT-1205

Frequency
2.4kHz
Voltage - Rated
5Vo-p
Current Rating
40mA
Size / Dimension
Square - 12.8mm L x 12.8mm W x 7.1mm H
Mounting Type
Surface Mount
Sound Pressure Level
87dB
Operating Mode
Continuous
Voltage Range
3 ~ 8Vo-p
Termination
Solder Pads
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Frequency
-
Other names
102-1199-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CT-1205-SMT-TR
Manufacturer:
CUIINC
Quantity:
20 000
Part Number:
CT-1205C
Manufacturer:
HRS
Quantity:
2 021
PART NUMBER: CT-1205
ENVIRONMENT TEST
item
high temp. test
low temp. test
thermal shock
temp. cycle test
RELIABILITY TEST
item
operating (life test)
TEST CONDITIONS
standard test condition
judgement test condition
20050 SW 112
th
Ave. Tualatin, Oregon 97062
a) temperature: +5 ~ +35°C
a) temperature: +25 ±2°C
test condition
After being placed in a chamber at +85°C for
96 hours.
After being placed in a chamber at -40°C for
96 hours.
The part will be subjected to 10 cycles. One
cycle will consist of:
The part will be subjected to 10 cycles. One
cycle will consist of:
test condition
1. Continuous life test:
The part will be subjected to 72 hours of
continuous operation at +70°C with 5 V,
2400 Hz applied.
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 10,000 times at room temp
(+25 ±10°C) with 5 V, 2400 Hz applied.
+85°C
+25°C
-40°C
30 min.
3hrs
a
a,b : 90~98%RH
c : 80~98%RH
phone
phone 503.612.2300 fax
12±0.5hrs
60 min.
b
DESCRIPTION: magnetic buzzer
24hours
30 min.
+85 ° C
b) humidity: 45 - 85%
b) humidity: 60 - 70%
3hrs
c
fax 503.612.2383
evaluation standard
evaluation standard
After the test, the part will meet
specifications without any
damage to its appearance and
performance. After 4 hours at
25°C, the SPL should be within
±10dB compared with the initial
measurement.
After the test, the part will meet
specifications without any
damage to its appearance and
performance. After 4 hours at
25°C, the SPL should be within
±10dB compared with the initial
measurement.
c) pressure: 860-1060 mbar
c) pressure: 860-1060 mbar
rev.
page
date
03/2010
3 of 5