Specifications of AP112-1R-36616-3

Breaker Type
Hydraulic-Magnetic
Voltage
50VDC, 240VAC
Number Of Poles
3
Actuator Type
Toggle
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Trip (it)
-
Other names
Q5448811
Introduction
Single Pole
Multi-Pole
Configurations
Operating Characteristics
Delay Curves
Specifications
Decision Tables
|
|
|
|
|
|
|
|
77
78
79
81
82
83
84
85
AP/UP, AP/MIL Series
Magnetic Circuit Protectors

Related parts for AP112-1R-36616-3

AP112-1R-36616-3 Summary of contents

Page 1

Introduction Single Pole Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables AP/UP, AP/MIL Series Magnetic Circuit Protectors ...

Page 2

... The Airpax™ AP series are fully sealed, magnetic circuit protectors that combine power switching and accurate, reliable circuit protection with inverse time delays and trip free features. Unlike a thermal circuit protector, the AP does not change its trip current over a wide temperature span. In addition, the AP ...

Page 3

Mounting Detail FOR PANEL INTEGRITY, THIS HOLE MUST BE BLIND WITH .075 [ 1.91 ] MIN. DEPTH . 325 .125 [ [ [ [ 3.18 8.26 . 391 [ [ 9.93 Panel Mounting Detail: Tolerance for Mtg. ±.005 [.13] Maximum ...

Page 4

MULTI-POLE CIRCUIT PROTECTORS AP Multi-Pole Combinations Circuit demands and design ingenuity suggest a limitless number of special combinations, ranging from a two pole unit with one series breaker and a simple ON·OFF switch more complex three pole unit ...

Page 5

... Some typical combinations could be: 3 series poles; 2 series and one shunt; 2 series and one relay series with a set of auxiliary contacts. Three Pole, AP112, Toggle 1.780 MAX ...

Page 6

CONFIGURATIONS Series Trip The most popular configuration for magnetic protectors is the series trip where the sensing coil and contacts are in series with the load being protected. The handle position conveniently indicates circuit status. In addition to providing conventional ...

Page 7

OPERATIONAL CHARACTERISTICS Inrush Pulse Tolerance The following table provides a comparison of inrush pulse tolerance with and without the inertial delay feature for each of the 50/60Hz delays. Pulse tolerance is defined as a single pulse of half sine wave ...

Page 8

TyPICAL DELAy CURvES The delay curves below illustrate our standard instant, short and long delays. Please consult factory for specific delay curves or refer to table on page 87. Delay curves 64 and 65 illustrate the improved inrush tolerance provided ...

Page 9

Trip free AP circuit protectors will trip open on overload, even when forcibly held ON. This prevents the operator from damaging the circuit by holding the handle in the ON position. Trip Indication The operating handle of the breaker moves ...

Page 10

HOW TO ORDER The ordering code for AP magnetic circuit protectors may be determined by following the steps in the decision tables shown here. For example, the following is the code for a two pole AP, hook terminal, series unit, ...

Page 11

Decision First Type AP Fully sealed magnetic circuit protector UP Underwriters' Laboratories (Note A) recognized circuit supplementary protector /1 through /6 QPL per AP - MIL (Note B) MIL-PRF-39019 2 Second Decision ( Note C ) Poles Hook Screw ...

Page 12

This document is generated from the AIRPAX™ full-line catalog #2455005000 printed in USA, January 2011 BUSINeSS CeNTeRS Sensata Technologies 807 Woods Road Cambridge, MD 21613, UsA phone: +1 410-228-1500 Brands: Airpax™ Sensata Technologies Inc. 529 Pleasant Street Attleboro, MA 02703, ...