4404.0028 Schurter Inc, 4404.0028 Datasheet

no-image

4404.0028

Manufacturer Part Number
4404.0028
Description
CIRCUIT BRKR SP RESET 15A THREAD
Manufacturer
Schurter Inc
Series
T9r
Type
Thermalr
Datasheets

Specifications of 4404.0028

Breaker Type
Thermal
Voltage
32/48VDC, 240VAC
Current - Trip (it)
15A
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
Panel Mount
Alt Mfr.s Type
T9-311C-15
Brand/series
T9 Series
Current, Rating
12 A
Dimensions
36.1mmWx13.6mmHx15.4mmD
Termination
Quick Connect
Voltage, Rating
240 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
T9-311C-15
T9-311C-15
2
Resettable Thermal Circuit Breaker, Single Pole, 4–16 A
Description
– Thermal circuit breaker
– Supplementary protector for general industrial use
– Cycling trip-free release
– Reset type
– Single pole
– Mounting style: T9-311: Threaded neck
Standards
– IEC 60934
– UL 1077
– CSA C22.2 235
– GB 17701
Technical Data
Typical internal resistance
Rated voltage
Rated current
Conditional short circuit capacitiy
Overload rating
Degree of protection
Endurance minimum
Endurance typical
Dielectric strength
Insulation resistance
Ambient temperature
Type of actuation
Type of tripping
Weight
T9-311: Threaded neck
Rated current
4 A
5 A
6 A
7 A
8 A
T9-611: Snap-in front side
T9-711: Snap-in rear side
Internal resistance
(mΩ)
21.6
23.6
16.3
15.3
12.9
T9-311 with cover TZZ31
circuit breakers
(see approvals)
IEC: Inc, PC1, AC 240 V
CSA: SC, AC 240 V / DC 48/32 V
According to CSA C22.2 235
Accessible range
Termination range
IEC: 200% In, cos phi 0.6
4–8 A: 150% In, cos phi 0.9
10–16 A: 150% In, cos phi 0.9
DC 500 V
5–16 A
4 A
Reset Type (manual)
Rated current
10 A
12 A
14 A
15 A
16 A
circuit breakers
Internal resistance
(mΩ)
Applications
– Power supplies
– UPS
– Power tools
– Household appliances
– Industrial appliances
– Medical diagnostic appliances
– HVAC
Weblinks
Approvals: http://www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
7.3
7.0
4.8
4.3
3.9
T9-611: Snap-in from front side
AC 240 V, 50/60 Hz
DC 48/32 V
4–16 A
2 kA
2 kA, C1
OL0 240 VAC
OL0 48 VDC and 32 VDC
IP 40
IP 00
min. 50 cycles
2500 cycles
6000 cycles
AC 1500 V
> 100 MΩ
-5 °C to 60 °C
-5 °C to 50 °C
R
Cycling trip-free
9 g
T9-711: Snap-in from back side

Related parts for 4404.0028

4404.0028 Summary of contents

Page 1

... A Reset Type (manual) Rated current Internal resistance (mΩ 3.9 circuit breakers T9-711: Snap-in from back side AC 240 V, 50/ 48/32 V 4– kA, C1 OL0 240 VAC OL0 48 VDC and 32 VDC min. 50 cycles 2500 cycles 6000 cycles AC 1500 V > 100 MΩ ...

Page 2

... Rated currents Rated voltage AC 4–12 A 240 V > 12–16 A 240 V 4–12 A 240 V > 12–16 A 240 V 4–12 A 240 V > 12–16 A 240 V 4–16 A 240 V circuit breakers Correction factor -5 0,85 0,95 1,00 1,08 1,21 10,0 A +60°C 1,21 10 1,21 = 12,1 A Rated voltage ...

Page 3

... Snap-in type from rear side (0.5…3.0 mm) Actuation type 1 Reset Type (R-type) Terminal type 1 6.3 x 0.8 mm quick connect terminals IEC 61210 Front printing C rated current not marked on front (T9-311 and T9-711) P rated current printed on front (T9-611 only) Rated current 10A circuit breakers ...

Page 4

... Panel thickness S = 0.8–5.5 mm T9-611 ±0.2 ø 15.4 3.4 8 +0.15 +0. Panel thickness S = 0.8–2.0 mm Recommended panel thickness: 0.8/1.2/1.6/2.0 mm T9-711 ±0.2 ø 15.4 3 13.9 -0.1 Panel thickness S = 0.5–3.0 mm www.schurter.com/pg17_18_19 36.1 10 6.3x0.8 max. torque 0 6.3x0.8 +0. 43.1 10 6.3x0.8 circuit breakers 19 3/8" -27UNS ...

Related keywords