Single pole thermal-magnetic circuit breaker with tease-free, trip-free,
snap action mechanism and two button operation (M-type TM CBE to
EN 60934). Designed for plug-in mounting with E-T-A sockets 17-P10-Si,
23-P10-Si, 63-P10-Si; or panel mounting using E-T-A clips. Featuring
an unprotected shunt tap terminal and optional auxiliary contacts. Type
3900 offers lower internal resistance values and is fitted as standard
with auxiliary contacts and an intermediate reset position in which all
contacts are isolated.
Approved to CBE standard EN 60934 (IEC 60934).
Process control systems, instrumentation, communications systems,
rail vehicles.
Type No.
3600
3900
3600 - P10 - Si -
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Current
rating (A)
0.05
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.5
2
2.5
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
standard version with shunt tap terminal -3
low-resistance version
Terminal design
P10
blade terminals 6.3-0.8 (QC .250)
Auxiliary contacts (3900: intermediate position as standard)
Si
Si60
ZR-Si
ZR-Si60
Si3-R
Internal resistance (Ω)
3600
447
131
40
19.3
10.4
7.1
4.3
2.5
1.67
0.61
0.38
0.24
with blade terminals 6.3-08,one each NO/NC,
special auxiliary contact (only 3900)
1 NO, closed in the intermediate and ON position
auxiliary contacts with intermediate position (only 3600)
special auxiliary contact (only 3600)
1 NO, closed in the intermediate and ON position
special auxiliary contacts, 2 NC contacts with reset
button (not approved)
Current ratings
0.05...16 A
0.05...10 A
10 A
Thermal-Magnetic Circuit Breakers 3600/3900
3900
211
48
12.4
5.4
3.1
2.0
1.32
0.76
0.49
0.21
0.101
0.078
ordering example
(type 3600)
(type 3900)
Current
rating (A)
3
4
5
6
7
8
10
12
14
15
16
Internal resistance (Ω)
3600
0.19
0.090
0.061
0.041
0.034
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
0.054
0.035
0.025
≤ 0.02
≤ 0.02
≤ 0.02
≤ 0.02
3900
www.e-t-a.com
Current rating range
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
Degree of protection
Humidity
For further details please see chapter: Technical Information
Voltage rating
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(UL 1077)
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Mass
Authority
3600:
VDE (EN 60934)
CSA/UL
UL
3900:
VDE (EN 60934)
Technical data
Approvals
operating area
main/aux. circuit
aux. circuit 4-5/6-7
type 3600:
standard type
cn
3600
Voltage ratings
AC 240 V; DC 65 V
AC 250 V; DC 80 V
DC 65 V
AC 240 V; DC 65 V
test voltage
AC 240 V, 50/60 Hz; DC 65 V
(UL: AC 250 V; DC 65 V)
3600: 0.05...16 A
3900: 0.05...10 A
1 A, AC 240 V / DC 65 V
5,000 operations at 1 x I
5,000 operations at 2 x I
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
AC 3,000 V
AC 1,500 V
AC 840 V
>100 MΩ (DC 500 V)
3600
0.05...0.8 A
1...2 A
2.5...16 A
I
0.05...16 A
0.05...16 A
operating area IP40
terminal area IP00
5 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
25 g (11 ms) to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 45 g
N
3900
low-resistance type
3900
0.05...0.2 A self-limiting
0.3...2 A
2.5...10 A
U
AC 250 V
DC 80 V
N
Current ratings
0.05...16 A
0.05...16 A
0.05...25 A
0.05...10 A
pollution
degree
2
N
N
, inductive
, resistive
200 A
400 A
1,000 A
1,000 A
2 - 57
2