1160-02-20A E-T-A, 1160-02-20A Datasheet

CIRCUIT BREAKER SP THERMAL 20A

1160-02-20A

Manufacturer Part Number
1160-02-20A
Description
CIRCUIT BREAKER SP THERMAL 20A
Manufacturer
E-T-A
Series
1160r
Datasheet

Specifications of 1160-02-20A

Breaker Type
Thermal
Voltage
12VDC
Current - Trip (it)
20A
Number Of Poles
1
Actuator Type
Automatic Reset
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1160-02-20AMP
302-1231
Thermal circuit breaker, with controlled self-resetting mechanism,
specially suited to installation in inaccessible locations. Under overload
conditions the circuit breaker contacts will open to protect the load
circuit. A low current excitation circuit ensures that the contacts remain
open thereby avoiding the hazards of automatic reset operation. The
circuit breaker is reset by switching off the supply circuit for a short
period. Class 2 device, contacts stay open until voltage is removed.
Type II to SAE J 553.
Automotive and marine extra low voltage wiring systems and components,
battery powered appliances.
Type No.
1160
1160 - 02 - 12A
Current rating (A)
12
15
20
30
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical voltage drop values
single pole plug-in type
Design standard
02
standard version 12 V
Current ratings
12, 15, 20, 30 A
ordering example
Thermal Automotive Circuit Breaker 1160-...
Voltage drop (mV)
< 150
< 150
< 150
< 150
www.e-t-a.com
Interrupting capacity
Shock
Corrosion
Humidity
Voltage rating
Current ratings
Typical life
Ambient temperature
Holding current
Reset time at 23°C after
5 s of load with U
(o-o-o)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Mass
Technical data
N
DC 12 V
12...30 A
300 operations at 2 x I
-30...+60 °C (-22...+140 °F)
< 0.6 A
< 35 sec
200 A, L/R = 2.5 ms
housing area IP54
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 6 g
1160-...
N
1 - 35
1

Related parts for 1160-02-20A

1160-02-20A Summary of contents

Page 1

... Ordering information Type No. 1160 single pole plug-in type Design standard 02 standard version 12 V Current ratings 12, 15, 20 1160 - 02 - 12A ordering example Standard current ratings and typical voltage drop values Current rating (A) Voltage drop (mV) 12 < 150 15 < 150 20 < 150 30 < ...

Page 2

... Thermal Automotive Circuit Breaker 1160-... Dimensions 25.1 .988 23.8 .937 1 9.3 .366 5.2 .205 Accessories Sockets available to special order Internal connection diagram Typical time/current characteristics at +23 °C/+73.4 °F 2.5 .098 0.8 .031 10000 1000 100 10 1 0.1 0.6 0.8 1 ... times rated current The time/current characteristic curve depends on the ambient temperature prevailing ...

Related keywords