6720005380 Weidmuller, 6720005380 Datasheet - Page 2

ELECT CIRCUIT PROTECTOR 24V .5A

6720005380

Manufacturer Part Number
6720005380
Description
ELECT CIRCUIT PROTECTOR 24V .5A
Manufacturer
Weidmuller
Series
ESX10-Tr
Datasheet

Specifications of 6720005380

Breaker Type
Thermal
Voltage
24VDC
Current - Trip (it)
500mA
Number Of Poles
1
Actuator Type
Push to Reset
Mounting Type
DIN Rail
Current Rating
0.5A
Supply Voltage
24VDC
No. Of Poles
1
Trip Time
3s
Load Current Max
500mA
Trip Time Max
7sec
Trip Time Min
3sec
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Operating data
Operating voltage U b
Current rating I n
Closed current I 0
Status indication
by means of
Load circuit
Load output
Overload disconnection
Short-circuit current I K
Trip time
Temperature disconnection
Low voltage monitoring
load output
Starting delay t
Disconnection of load circuit
Free-wheeling circuit
Several load outputs must not be connected in parallel
Approvals
UL 2367
UL 1604 (class I, div. 2, zone 2)
UL508 and CSA in process
Technical data
2
Authority
for electronic disconnection
E l e c t r o n i c C i r c u i t P r o t e c t i o n
start
(T ambient = 25°C, operating voltage U b = 24VDC)
24VDC (18...32 V)
fixed current ratings: 0.5, 1 A, 2 A, 3 A, 4 A,
ON condition: typically 20...30 mA
depending on signal output
• multicolour LED:
• status output SF (option)
• potential-free signal contact F (option)
• ON/OFF/ condition of switch S1
Power-MOSFET switching output
(high side switch)
typically 1.1 x I n (1.05...1.35 x I n )
active current limitation (see table 1)
see time/current characteristics
typically 3 s at I
typically 3 s...100 ms at I
internal temperature monitoring with
electronic disconnection
with hysteresis, no reset required
load “OFF” at U b < 8 V
typically 0.5 sec after every switch-on
and after applying U b
electronic disconnection
external free-wheeling diode
recommended with inductive load
Voltage rating
24VDC
24VDC
GREEN: unit is ON, power-MOSFET
ORANGE: in the event of overload or
RED: - unit electronically disconnected
OFF:
(or 1.5 x I n /1.3 x I n )
- status output SF ON,
- load circuit/Power-MOSFET
- manually switched off
- undervoltage (U b < 8 V)
- after switch-on till the end
is switched on
supplies + 24VDC
short circuit until electronic
disconnection
OFF
(S1 = OFF)
or device is dead
of the delay period
Load
> 1.1 x I n
6 A, 8 A, 10 A, 12 A
Load
> 1.8 x I n
Current ratings
0.5...12 A
0.5...12 A
Technical data
Status output SF
Electrical data
Status OUT
OFF condition
Signal output F
Electrical data
ON condition LED green
OFF condition LED off
Fault condition LED orange
Fault condition LED red
ESX10-TB-101
ESX10-TB-102
Fault
Reset input RE
Electrical data
Reset signal RE
(terminal 22)
Control input IN+
Electrical data
Control signal IN+
(terminal 21)
Switch S1 ON/OFF
(T ambient = 25°C, operating voltage U b = 24VDC)
ESX10-TB-114/-124/
plus-switching signal output,
connects U b to terminal 12 of module 17plus
nominal data: 24VDC / max. 0.2 A (short circuit proof)
status output is internally connected to
GND with a 10 kOhm resistor
ESX10-TB-114/-124 (signal status OUT),
at U b = +24 V
+24 V = S1 is ON, load output connected through
0V = S1 is ON, load output blocked and/or
switch S1 is OFF
red LED lighted
0 V level at status output when:
• switch S1 is in ON position, but device is
• switch S1 is OFF, or control signal OFF,
• no operating voltage U b
ESX10-TB-101/-102
potential-free signal contact
max. 30VDC/0.5 A, min. 10 V/10 mA
voltage U b applied, switch S1 is in ON position
no overload, no short circuit
• device switched off (switch S1 is in OFF position)
• no voltage U b applied
overload condition > 1.1 x I n up to
electronic disconnection
electronic disconnection upon
overload or short circuit
device switched off with control signal
(switch S1 is in ON position)
single signal, make contact
contact SC/SO-SI open
single signal, break contact
contact SC/SO-SI closed
signal output fault conditions:
• no operating voltage U b
• ON/OFF switch S1 is in OFF position
• red LED lighted
ESX10-TB-124
voltage: max. +32VDC
high > 8VDC ≤ 32VDC
low ≤ 3VDC > 0 V
power consumption typically 2.6 mA
(+24VDC)
min. pulse duration typically 10 ms
The electronically blocked ESX10-TB-124
may remotely be reset via an external
momentary switch due to the falling edge of
a +24 V pulse.
A common reset signal can be applied to
several devices simultaneously.
Switched on devices remain unaffected.
ESX10-TB-114
see reset input RE
+24V level (HIGH): device will be switched
on by a remote ON/OFF signal
0 V level (LOW): device will be switched
off by a remote ON/OFF signal
unit can only be switched on with S1 if a
HIGH level is applied to IN+
still in switch-on delay
device is switched off
(electronic disconnection)
E S X 1 0 - T

Related parts for 6720005380