1410-L210-L2F1-S02-10A E-T-A, 1410-L210-L2F1-S02-10A Datasheet

CIRCUIT BREAKER PC MNT 10A

1410-L210-L2F1-S02-10A

Manufacturer Part Number
1410-L210-L2F1-S02-10A
Description
CIRCUIT BREAKER PC MNT 10A
Manufacturer
E-T-A
Series
1410r

Specifications of 1410-L210-L2F1-S02-10A

Breaker Type
Thermal
Voltage
50VDC, 250VAC
Current - Trip (it)
10A
Number Of Poles
1
Actuator Type
Lever
Mounting Type
PCB
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
1410-L210-L2F1-S02-10AMP
1410L210L2F1S0210A
302-1031
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934). Single
hole threadneck, PCB or integral mounting with a choice of designs.
Miniaturised construction minimises PCB real estate required. Type
1410-L2 and 1410-G1 versions feature changeover contacts suitable for
providing status output signals. Largely temperature-insensitive.
Motors, transformers, solenoids, PCBs, hand-held machines, appliances,
instrumentation.
Type No.
1410
1410 - L 2 1 0 - L2 F1 - S 02 - 0.8 A
*mounting hardware bulk shipped
Current
rating (A)
0.63
0.8
1
1.5
1.8
2
2.5
Issue B
Description
Typical applications
Ordering information
Standard current ratings and typical internal resistance values
single pole circuit breaker
Configuration
L
G
PCB mounting or integral mounting
threadneck panel mounting or PCB mounting
Mounting
1
2
3
threadneck 3/8-27UNS-2A (1410-G)
PCB 10.15x7.62 (1410-L)
PCB 10.15without shunt terminal (1410-L)
Number of poles
1
1-pole, thermally protected
Hardware
0
1
2
4
8
Internal
resistance (Ω)
1.8
1.7
1.3
< 1
< 1
< 1
< 0.15
without
with hexnut and knurled nut (only1410-G)
> 5 pcs
without hexnut and knurled nut and without shunt
terminal (only 1410-G)
with hexnut and knurled nut,
without shunt terminal (only 1410-G)
with actuator guard and marking CB..
(only 1410-G)
Terminal design
L2
P2
P3
solder pins 1x0.8 silver-plated
blade terminals DIN 46244-A2.8-0.8 silver-plated (only -G)
blade terminals DIN 46244-A4.8-0.5 silver-plated (only -G)
Characteristic curve
F1
Thermal Overcurrent Circuit Breaker 1410-L2/G1
hexnut and knurled nut
fast acting
Actuator
B
S
flat reset-slide (only 1410-G)
reset slide/button
Actuator colour
01
02
04
black (for -G1..)
white (for -L2..)
red (for 1410-G..-...B)
Current ratings
0.63...10 A
Current
rating (A)
3.15
4
5
6.3
8
10
ordering example
bulk shipped
Internal
resistance (Ω)
< 0.12
< 0.1
< 0.1
< 0.1
< 0.1
< 0.1
www.e-t-a.com
Typical life
Dielectric strength
(IEC 60664 and 60664A)
Shock
Corrosion
Humidity
For further details please see chapter: Technical Information
Voltage rating
Current rating range 1-2
Auxiliary circuit 1-3
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(o-o-o)
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Mass
Authority
VDE
UL, CSA
Technical data
Approvals
AC 240 V: 0.63...2.25 A 500 break operations at 2 x I
DC 50 V: 0.63...2.25 A 500 break operations at 2 x I
DC 28 V: 2.5...10 A
operating area
1410-L2...
2.5...10 A
cn
Voltage rating
AC 240 V
DC 50 V
DC 28 V
AC 250 V; DC 50 V
AC 240 V; DC 28 V
(UL: AC 250 V; DC 50 V)
0.63...10 A
0.2 x I
500 break operations at 2 x I
500 break operations at 2 x I
-20...+70 °C (-4...+158 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 1,500 V
> 100 MΩ (DC 500 V)
0.63...2 A
2.5...8 A
10 A
3.15...10 A
0.63...10 A
0.63...10 A
operating area IP40
terminal area IP00
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
20 g (11 ms)
to IEC 60068-2-27, test Ea
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
96 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 5 g
N
max. 1 A, AC 250 V
12 x I
8 x I
6 x I
10 x I
2,000 A
200 A
1410-G1...
N
N
N
, AC max. 50 A
, AC
N
Current ratings
0.63...10 A
0.63...2 A
2.5...10 A
0.63...10 A
, DC
pollution
degree
2
AC 250 V
DC 50 V
N
N
N
N
, inductive
, resistive
, inductive
, inductive
1 - 49
1

Related parts for 1410-L210-L2F1-S02-10A

1410-L210-L2F1-S02-10A Summary of contents

Page 1

... Actuator colour 01 black (for -G1..) 02 white (for -L2..) 04 red (for 1410-G..-...B) Current ratings 0.63...10 A 1410 - 0.8 A ordering example *mounting hardware bulk shipped Standard current ratings and typical internal resistance values Current Internal Current rating (A) resistance (Ω) rating (A) 0.63 1 ...

Page 2

... Thermal Overcurrent Circuit Breaker 1410-L2/G1 Dimensions 1410-L210-L2F1-S02 33 1.30 30 1. 0.8 .039 .031 6.4 10.15 .252 .400 7.6 .299 1410-G111-P2F1-S01 tightening torque max. 0.8 Nm 3/8-27UNS-2A ø7 .276 2.8 0.8 .110 .031 10.15 6.4 blade terminal .252 .400 DIN 46244-A2.8-0.8 7.6 (QC .110) ...

Related keywords