LC01-6.TDT Semtech, LC01-6.TDT Datasheet - Page 4

IC TVS FOR HI-SPD TELECOM 16SOIC

LC01-6.TDT

Manufacturer Part Number
LC01-6.TDT
Description
IC TVS FOR HI-SPD TELECOM 16SOIC
Manufacturer
Semtech
Datasheet

Specifications of LC01-6.TDT

Voltage - Reverse Standoff (typ)
6V
Voltage - Breakdown
8V
Power (watts)
1500W
Polarization
2 Channel Array - Bidirectional
Mounting Type
Surface Mount
Package / Case
16-SOIC
Clamping Voltage Vc Max
16V
Operating Voltage
6V
Diode Case Style
SOIC
No. Of Pins
16
Breakdown Voltage Min
8V
Breakdown Voltage Vbr
8V
Capacitance, Cd
50pF
Junction Capacitance
50pF
Rohs Compliant
Yes
Diode Type
Low Capacitance
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
LC01-6TR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
LC01-6.TDT
Quantity:
143
LC01-6
PROTECTION PRODUCTS
Applications Information
Device Connection Options for Protection of High-
Speed Data Lines
The LC01-6 is designed to protect high-speed data
lines from transient over-voltages which result from
lightning and ESD. The device is designed to protect
one line pair in differential (Line-to-Line) mode. Pins 1-
8 are connected to line 1 and pins 9-16 are connected
to line 2 as shown. All pins should be connected for
best results.
T1/E1 Linecard Protection
A typical long-haul T1/E1 linecard protection circuit is
Figure 1 - Schematic and Pin Configuration
shown below. The LC01-6 is connected between Tip
and Ring on the transmit and receive line pairs. It
provides protection to metallic (line-to-line) lightning
surges per Bellcore 1089 and FCC Part 68. Depending
on the application, a high voltage crowbar device (not
shown) such as a gas discharge tube (GDT) or TVS
Thyristor may be used to suppress common mode (line-
to-ground) surges. To complete the protection circuit,
the SRDA05-4 (or SRDA3.3-4 for 3.3V supplies) is
employed as the secondary IC side protection element.
This device helps prevent the transceiver from latching
up by providing fine clamping of transients that are
coupled through the transformer. Positive temperature
coefficient (PTC) resistors or fuses are also required for
AC power cross protection. For further information,
reference Semtech application note AN97-10.
Figure 2 - Connection for Differential Protection
(Line-to-Line)
www.semtech.com
2004 Semtech Corp.
4