VPS28-1500 Triad Magnetics, VPS28-1500 Datasheet

XFRMR PWR 28.0VCT 1.5A QC .187

VPS28-1500

Manufacturer Part Number
VPS28-1500
Description
XFRMR PWR 28.0VCT 1.5A QC .187
Manufacturer
Triad Magnetics
Series
Chassis Mount: World Series™r
Type
Standardr
Datasheets

Specifications of VPS28-1500

Maximum Power
43 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, Center Tap
Series Output Voltage @ Current
28 VAC @ 1.5A
Parallel Output Voltage @ Current
14 VAC @ 3A
Mounting Type
Chassis Mount
Power Rating
43 VA
Product
World Series Transformers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
237-1279
VPS28-1500
Electrical Specifications (@25C)
1. Maximum Power: 43VA
2. Input Voltage: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output Voltage: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements.
Safety:
These units are designed with 4000VAC isolation between the primary and
secondary, and also, between each winding and the core.
Agency File:
UL: File E53148, UL 5085-1 and 2 (formerly UL 506), General Purpose.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV Certificate No.: R72072385, EN60950, Information Technology
A. Dimensions:
B. Mounting Hole Size: 3/16”
C. WT Lbs. : 1.6
Connections
Input: Series – 6 and 1, Jumper 5 to 2
Output: Series – 12 and 7, Jumper 11 to 8
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
2-11/16
Non-Inherently limited. Class 3.
Non-Inherently limited. Class 2 not wet, Class 3 wet.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
H
File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3
Parallel – 6 and 1, Jumper 6 to 2 and 5 to 1
Parallel – 12 and 7, Jumper 12 to 8 and 11 to 7
Series: Littelfuse p/n 313 2 HXP, 2.0A 250V, slow blow, ¼ x 1 ¼ or,
Parallel: Littelfuse p/n 313 4 HXP, 4A 250V, slow blow, ¼ x 1 ¼ or,
3-1/8
W
4
:
Cooper Bussmann p/n BKMDL-2, 2A 250V, ¼ x 1 ¼
Cooper Bussmann p/n BKMDL-4, 4A 250V, ¼ x 1 ¼
3
D
2
:
1
: 28.0V CT@ 1.5A; Parallel
2-5/16
A
22520B Temescal Canyon Road
Corona, California
92883
1-1/8
B
5/16
C
2
: 14.0V @ 3.0A
P O W E R T R A N S F O R M E R
CHASSIS MOUNT :
QUICK-CONNECT WORLD SERIES
3/16
T
Unit: In inches
2-13/16
MW
Release Date: October 12, 2009
ML
-
H
6
5
1
2
6
5
2
1
SCHEMATIC
MW
W
D
B
A
T
C
12
11
8
7
12
11
8
7

Related parts for VPS28-1500