VPP36-820 Triad Magnetics, VPP36-820 Datasheet

TRANSF 18VAC 1.64A WORLD SERIES

VPP36-820

Manufacturer Part Number
VPP36-820
Description
TRANSF 18VAC 1.64A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP36-820

Maximum Power
30 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
36 VAC @ 820mA
Parallel Output Voltage @ Current
18 VAC @ 1.64A
Mounting Type
Through Hole
Power Rating
30 VA
Product
World Series Transformers
Mounting Style
SMD/SMT
Dimensions
2.187 in L x 2.625 in W x 1.562 in H
Height
1.562 in
Length
2.187 in
Termination Style
Solder
Width
2.625 in
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10493
237-1080
VPP36–820
Electrical Specifications (@25C)
1. Maximum Power: 30.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
8. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.045 SQ
C. WT Lbs. : 1.15
D. Mounting Holes: 0.156 dia. x 4
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
Inherently limited. Class 3.
Non-Inherently limited. Class 2 not wet, Class 3 wet.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
1.562
orld Series Transformers are designed and manufactured to meet the following agency approvals:
H
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
2.625
W
Series: Inherently limited. No fusing required.
Parallel: Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or,
4
:
1
: 36.0V CT@ 0.82A; Parallel
2.187
Cooper Bussmann p/n BKMDL-2½, 2.5A 250V, ¼ x 1 ¼
D
3
:
0.550
A
0.275
B
22520B Temescal Canyon Road
Corona, California
92883
1.680
2
: 18.0V @ 1.64A
C
ML
-
1.75
Units: In inches
MD
2.187
P
P C M
MW
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
6
4
3
1
SCHEMATIC
S
E R I E S
12
10
9
7

Related parts for VPP36-820