VPP20-1000 Triad Magnetics, VPP20-1000 Datasheet

TRANSF 10VAC 2A WORLD SERIES

VPP20-1000

Manufacturer Part Number
VPP20-1000
Description
TRANSF 10VAC 2A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP20-1000

Maximum Power
20 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
20 VAC @ 1A
Parallel Output Voltage @ Current
10 VAC @ 2A
Mounting Type
Through Hole
Power Rating
20 VA
Primary Voltage Rating
230 VAC, 115 VAC
Secondary Voltage Rating
20 V
Mounting Style
PCB
Dimensions
2.25 in L x 1.875 in W x 1.625 in H
Product
World Series Transformers
Height
1.625 in
Length
2.25 in
Termination Style
Through Hole
Width
1.875 in
Transformer Type
Power
Input Voltage
115V
Output Voltage
20V
Current Rating
2A
Transformer Mounting
PC Board
Secondary Current Nom
2A
Primary Voltages
115 / 230V
Rohs Compliant
Yes
Secondary Voltages
2 X 10V
Leaded Process Compatible
Yes
Output Current
2A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10483
237-1070
VPP20–1000
Electrical Specifications (@25C)
1. Maximum Power: 20.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
8. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.036 SQ
C. WT Lbs. : 0.90
D. Mounting Holes: .112 dia. x 2.
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
1.500
L flammability requirements.
Non-Inherently limited. Class 2.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
orld Series Transformers are designed and manufactured to meet the following agency approvals:
Inherently limited. Class 2 not wet, Class 3 wet.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
A
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
1.625
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
B
Series: Inherently Limited. No fusing required.
Parallel: Littelfuse p/n 313 2.5HXP, 2.5A 250V, slow blow, ¼ x 1 ¼ or,
4
:
1
: 20.0V CT@ 1.00A; Parallel
.187
C
Cooper Bussmann p/n BKMDL-2½, 2.5A 250V, ¼ x 1 ¼
3
:
.400
D
.400
E
1.875
F
22520B Temescal Canyon Road
Corona, California
92883
2
: 10.0V @ 2.0A
2.250
Units: In inches
G
1.460
H
P
P C M
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
4
6
3
1
SCHEMATIC
1
3
4
6
c
S
B
F
R
E R I E S
A
US
H
10
12
R
7
9
C
G
E
12
10
D
D
9
7