VPP28-720 Triad Magnetics, VPP28-720 Datasheet

TRANSF 14VAC 1.44A WORLD SERIES

VPP28-720

Manufacturer Part Number
VPP28-720
Description
TRANSF 14VAC 1.44A WORLD SERIES
Manufacturer
Triad Magnetics
Series
PC Mount: World Series™r
Type
Dual Primaryr
Datasheets

Specifications of VPP28-720

Maximum Power
20 VA
Primary Winding(s)
Dual
Secondary Winding(s)
Dual, No Center Tap
Series Output Voltage @ Current
28 VAC @ 720mA
Parallel Output Voltage @ Current
14 VAC @ 1.44A
Mounting Type
Through Hole
Power Rating
20 VA
Product
World Series Transformers
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
10485
237-1072
VPP28–720
Electrical Specifications (@25C)
1. Maximum Power: 20.0VA
2. Input: Series: 230VAC, 50/60Hz; Parallel: 115VAC, 50/60Hz
3. Output: Series
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 30C TYP (45C MAX allowed)
6. Insulation Resistance: 100MΩ
7. Hipot: 4000VAC between primary to secondary and windings to core.
8. Recommended Fuse
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature material that exceeds
U
Safety:
Since the dual bobbin construction effectively reduces capacitance, electrostatic shielding is not required.
W
Agency File:
UL: File E53148, UL 5085-1 and 3 (formerly UL 506), General Purpose.
UL: File E65390, UL 5085-1 and 3 (formerly UL1585), Class 2/3.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
TUV: File R 72072385, EN 60950, (IEC950) information Technology Equipment.
A. Dimensions:
B. PIN DIM. : 0.036 SQ
C. WT Lbs. : 0.90
D. Mounting Holes: .112 dia. x 2.
Connections
Input:
Output:
RoHS Compliance: Meets the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for
the most current version.
1
2
3
4
intended to be used independently.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
1.500
Inherently limited. Class 3 wet.
Non-Inherently limited. Class 2 wet, Class 3 wet.
Fuse must be used on secondary as conditions of acceptability for UL Class2/3 operation.
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
L flammability requirements.
orld Series Transformers are designed and manufactured to meet the following agency approvals:
A
Series – Pin 7 to Pin 12, Jumper Pin 9 to Pin 10
1.625
Parallel – Pin 1 to Pin 6, Jumper Pin 1 to Pin 4 and Pin 3 to Pin 6
Parallel – Pin 7 to Pin 12, Jumper Pin 7 to Pin 10 and Pin 9 to Pin 12
Series – Pin 1 to Pin 6, Jumper Pin 4 to Pin 3
B
Series: Inherently Limited. No fusing required.
Parallel: Littelfuse p/n 313 2HXP, 2.0A 250V, slow blow, ¼ x 1 ¼ or,
4
:
1
: 28.0V CT@ 0.72A; Parallel
.187
C
Cooper Bussmann p/n BK/MDL-2, 2.0A 250V, ¼ x 1 ¼
3
:
.400
D
.400
E
1.875
F
22520B Temescal Canyon Road
Corona, California
92883
2
: 14.0V @ 1.44A
2.250
Units: In inches
G
1.460
H
P
P C M
O W E R
O U N T :
T
Publish Date: August 3, 2009
R A N S F O R M E R
W
O R L D
4
6
3
1
SCHEMATIC
1
3
4
6
c
S
B
F
R
E R I E S
A
US
H
10
12
R
7
9
C
G
E
12
10
D
D
9
7

Related parts for VPP28-720

Related keywords