Specifications of 88865145

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4
2/34
Chronos 2 electronic timers - 22.5 mm
Non stocked items, minimum order quantity 100 units.
Relay output 1 DTDP relay
Technical specifications
Timing
Repetition accuracy (with constant
parameters)
Drift
- Temperature
- Voltage
Display precision according to IEC 1812-1
Minimum pulse duration
- Typically (relay version)
- Typically (solid state version)
- Typically under load (relay version)
Maximum reset time by de-energisation
- Typically (relay version)
- Typically (solid state version)
Immunity to breaks in supply voltage: typically
Power supply
Multi-voltage power supply
Frequency
Operating range
Load factor
Maximum power consumption
Output elements relay output
1 or 2 changeover relays, AgNi (cadmium-free)
Rated power
Maximum breaking current
Minimum breaking current
Voltage breaking capacity
Electrical life
Mechanical life
Breakdown voltage acc. to IEC 1812-1
Impulse voltage acc. to IEC 664-1 IEC 1812-1
Display
State displayed by 2 LEDs
- Flashing green when on
- Relay LED yellow during timing
Green LED operation indicator
- timer on, no timing in progress
- timing in progress
- Relay waiting, no timing in progress
Input type
- Volt-free contact
- 3-wire PNP output control option maximum
residual voltage: 0.4 V whatever the timer
power supply
(except functions Di-D and Li-L)
Multi-function or mono-function
Multi-range (7 ranges, available options)
Multi-voltage
Output 1 relay: 8 A - 250 V (10 A UL)
Screw or spring terminals
1 LED status indicators
Option of connecting an external power supply to the
control input
3-wire sensor control option
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
Pulsing:
Flashing:
Permanently lit:
Other information
Products and specifications subject to change without notice.
Consult factory for application assistance.
± 0.5 %
(CEI 1812-1)
± 0.05 % / °C
± 0.2 % / V
±10 % / 25 °C
30 ms
50 ms
100 ms
100 ms
350 ms
>10 ms
depending on version,
see page 1/17
50/60 Hz
85 to 110 % Un
(85 to 120 % Un for
12V AC/DC)
100 %
0.6 W 24V AC/DC
1.5 W 230V AC
32 VA 230V AC
2000 VA / 80 W
2000 V A / 80W
10 A AC 10 A DC
10 mA / 5 VDC
250V AC/VDC
10
8 A 250V resistive
5 x 10
2.5 kV / 1min /
1 mA /50Hz
5 kV, wave 1.2 / 50 s
0.4 V
5
operations
6
operations
Types
Screw terminal
Spring terminal
Part numbers and voltage
24V dc / 24 • 240V ac
12 V ac / dc
12 • 240 V ac /d c
Functions
Nominal current
Timing ranges
0.1s - 1s - 10 s , 6s - 60s , 1 min - 10 min , 6min - 60min , 1 h - 10 h - 100 h
TQR1: Selectable switching time
Timing
General specifications
Conforming to standards
IEC 1812-1, EN 50081-1/2, EN 50082-1/2, LV
directives (73/23/EEC + 93/68/EEC
(CE marking) + EMC (89/336/EEC +
IEC 669-2-3 (17.5 mm)
Approvals
UL - CSA - cUL listed
Temperatures limits
- use
- stored
Installation category (acc. to IEC 664-1)
Creepage distance and clearance acc. to
IEC 664-1
Degree of protection acc. to IEC 529
- terminal block
- casing
- front face (except Tk2R1)
Vibration resistance acc. to IEC 68-2-6
Relative humidity acc. to IEC 68-2-3
without condensation
Electromagnetic compatibility
- Immunity to electrostatic discharges acc. to
IEC 1000-42
- Immunity to electrostatic fields acc. to
ENV 50140/204 (IEC 1000-4-3)
- Immunity to rapid transient bursts acc. to IEC
1000-4-4
- Immunity to shock waves on power supply
acc. to IEC 1000-4-5
- Immunity to radiofrequency in common mode
acc. to ENV
- Immunity to voltage dips and breaks acc. to
IEC 1000-4-11
- Mains-borne and radiated emissions acc. to
EN 55022 (EN 55011 Group 1)
Fixing: Symmetrical DIN rail (EN 50022)
Connection capacity
- without ferrule
- with ferrule
Spring terminals, 2 terminals per
connection point
- flexible wire
- rigid wire
Casing material
Weight: 22.5 mm casing
20 / 40 / 60 / 80 / 100 / 120 / 140 ms
(7 ranges)
TUR1
Multi-function
A-At - B - C - H-Ht
Di-D - Ac - Bw
0.1s • 100h
88 865 105
1 0 A
-
-
-
TAR1
Bifunction
A - At
0.1s • 100h
88 865 115
1 0 A
-
-
-
-20 °C + 60 °C
-30 °C + 60 °C
Voltage surge
category
4 kV / 3
IP 20
IP 40
IP 50
f = 10 • 55 Hz
A = 0.35 mm
93 %
Level III
(Air 8 K /
Contact 6 KV)
Level III 10V/m:
80 MHz to 1 GHz)
Level III (direct 2kV/
Capacitive coupling
clamp 1 KV)
Level III (common
mode 2 KV / residual
current mode 1KV)
Level III (10V rms:
0.15 MHz to 80 MHz)
30 % / 10 ms
60 % / 100 ms >
95 % / 5 s
Class B
35 mm
2 x 2.5 mm
2 x 1.5 mm
1.5 mm
2.5 mm
Self-extinguishing
90 g
TBR1
Mono-function
B
0.1s • 100h
2
2
88 865 125
2
2
-
-
-
1 0 A

Related parts for 88865145

88865145 Summary of contents

Page 1

... Power supply Multi-voltage power supply Frequency Operating range Load factor Maximum power consumption Output elements relay output changeover relays, AgNi (cadmium-free) Rated power Maximum breaking current Minimum breaking current Voltage breaking capacity Electrical life Mechanical life Breakdown voltage acc. to IEC 1812-1 Impulse voltage acc ...

Page 2

TCR1 THR1 TLR1 - - 88 865 135 88 865 145 88 865 155 - - - - Mono-function Bifunction Bifunction ...

Page 3

... Chronos 2 electronic timers - 22.5 mm Relay output 2 DPDT relays Multi-function or mono-function Multi-range (7 ranges, available options) Multi-voltage Relays output 250 V (10 A UL) including 1 instantaneous Screw terminals 1 LED status indicators Option of connecting an external power supply to the control input 3-wire sensor control option Technical specifications ...

Page 4

... TK2R1 TU2R4 - 88 865 265 - 88 865 300 Mono-function Multi-function timers 2 timers including 1 instantaneous Function Ac Timing after closing and opening of control contact 2 timers or 2 relays, including 1 instantaneous R1/R2 R1/R2 R2 inst. R2 Inst. T ∞ Function D Flip-flop Pause start 2 timers or 2 relays, including 1 instantaneous U U R1/R2 ...

Page 5

... Delay OFF (with constant supply 1 relay R1/R2 R2 inst. 2 relays timed or 1 relay timed and 1 instantaneous Repeat cycle - Flip-flop 1 relay R1/ relays timed or R2 Inst. 1 relay timed and 1 instantaneous 1 relay R1/R2 2 relays timed relay timed and 1 instantaneous 2 Inst. Timing on energisation Interval timer - one shot 1 relay ...

Page 6

... Repetitive cycle comprising 2 independent adjustable time bases. Each time base corresponds alternately to a different output state. N.B. : The cycle starts with the output in the operating position. 2 relays timed or 1 relay timed and 1 instantaneous Function N : "Safe-guard" At the first control pulse the output is energised. ...

Related keywords