S1DXM-A4C10M-AC120V Panasonic Electric Works, S1DXM-A4C10M-AC120V Datasheet

no-image

S1DXM-A4C10M-AC120V

Manufacturer Part Number
S1DXM-A4C10M-AC120V
Description
RELAY TIMER ANALOG 4PDT 0-10MIN
Manufacturer
Panasonic Electric Works
Series
S1DXMr
Datasheet

Specifications of S1DXM-A4C10M-AC120V

Relay Type
Integrated
Function
On-Delay
Circuit
4PDT (4 Form C)
Delay Time
0.05 Sec ~ 10 Min
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
100 ~ 120VAC
Mounting Type
Socket
Termination Style
Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
’06–’07
Timers/Time Switches/Counters/Hour Meters
Timers/Time Switches/Counters/Hour Meters
ARCT1B274E ’06.10
Matsushita Electric Works, Ltd.

Related parts for S1DXM-A4C10M-AC120V

S1DXM-A4C10M-AC120V Summary of contents

Page 1

Timers/Time Switches/Counters/Hour Meters Timers/Time Switches/Counters/Hour Meters ARCT1B274E ’06.10 ’06–’07 Matsushita Electric Works, Ltd. ...

Page 2

... Further cost reduction when used with HJ Relay terminal socket marking supported UL and C-UL approved. Timed-out 4 Form C Part number S1DXM-A4C10M-DC12V S1DXM-A4C30M-DC12V S1DXM-A4C60M-DC12V S1DXM-A4C10H-DC12V S1DXM-A4C10M-DC24V S1DXM-A4C30M-DC24V S1DXM-A4C60M-DC24V S1DXM-A4C10H-DC24V S1DXM-A4C10M-AC24V S1DXM-A4C30M-AC24V S1DXM-A4C60M-AC24V S1DXM-A4C10H-AC24V S1DXM-A4C10M-AC120V S1DXM-A4C30M-AC120V S1DXM-A4C60M-AC120V S1DXM-A4C10H-AC120V S1DXM-A4C10M-AC220V S1DXM-A4C30M-AC220V S1DXM-A4C60M-AC220V S1DXM-A4C10H-AC220V S1DXM-A4C10M-AC240V S1DXM-A4C30M-AC240V S1DXM-A4C60M-AC240V S1DXM-A4C10H-AC240V 57 ...

Page 3

... S1DXM-A/M 2. S1DXM-M multi-range timer With MODE switch, Operation mode (switchable): Power ON-delay, Power Flicker ON start, Power Flicker OFF start, Power One-shot Operating voltage Time range 0. min 0 min 12V DC 0 min 0.05 min 0. min 0 min 24V DC 0 min 0.05 min 0. min 0 min 24V AC 0 ...

Page 4

... OPERATION MODE 1. S1DXM-A multi-range timer Power ON-delay operation • When power is turned on, the output contact operates after the set time. The output contact remains on until the power is turned off. Time chart ON Power supply OFF T ON Timed-out contact (NO) OFF UP (operation) LED ON (power) LED 2 ...

Page 5

... IEC standard: IP40 (IP50 when using ADX18008 protective cover) Specifications 220 to 240VAC 12VDC — Max Max (at 220 VAC) (at 12 VDC) Approx. 3mA Approx. 5mA Approx. 13mA Approx. 70mA S1DXM-A S1DXM-M +14 to +122°F) Min times on 3 axes) (5 times on 3 axes) 2 Max. 0.1s 70°C 158°F +14 to 122°F 3 Approx ...

Page 6

... DIMENSIONS 1. S1DXM-A Control time scale UP LED (orange) Time range switch 22.1 .870 ON LED (green) 28.5 1.122 Nameplate 52.7 2.075 6.4 .252 2. S1DXM-M Control time scale UP LED (orange) Time range switch Operation mode switch 22.1 .870 ON LED (green) 28.5 1.122 Nameplate 52.7 2 ...

Page 7

... S1DXM-A/M Precautions during usage 1. Reset periods After unscheduled operations have been completed the timer operation power supply has been turned off at any time during operation, a reset period of at least 0.1 seconds should be allowed before resuming operation. 2. External surge protection External surge protection may be required if the following values are exceeded ...

Page 8

... ADX18003 • HJ2 terminal socket 86.0 3.386 88.0 3.465 HJ2-SFD/HJ2-SFD-S SOCKET LINE HOLDING CLIP FOR S1DXM-A/M ADX28005 Dimensions Dimensions 7.5 .295 52.6 2.071 4.5 .177 21.2 .835 • HJ4 terminal socket 86.0 3.386 88.0 3 ...

Page 9

... S1DXM-A/M/S1DX COMMON OPTIONS HC relay terminal sockets Name/Part No. • Terminal socket, HC Oval hole: 2-4.2×5 2-pin .165×.197 HC2-SF-K 1.181 Note) Only wire springs can be used. (Plate springs cannot be used.) Oval hole: 2-4.2×9 • High terminal socket, .165×.354 HC 1-, 2- and 4-pin 22 ...

Page 10

... HJ4-SFD 1.142 • HJ4 terminal socket (Finger protect type) 2-M4.2×5 .165×5 mounting holes HJ4-SFD-S 1.142 S1DXM-A/M/S1DX COMMON OPTIONS Dimensions Terminal layout 30 1.181 M3 .118 16.5 terminal screw .650 ±0.3 3.4 ±.012 .134 ±1 72 ±.039 2.835 35.4 1.394 ±1 59 ± ...

Page 11

... S1DXM-A/M/S1DX COMMON OPTIONS Sockets Name/Order No. • Socket, HC 2-pin • The difference between the HC2 and HC4 sockets is only the number of the pins. Their appearances and sizes are the same 29.4 1.157 HC2-SS-K • Socket, HC 4-pin 29.4 1.157 HC4-SS-K • Sockets for PC board HC2 – ...

Page 12

... Flicker LT4H (Signal) LT4H-W LT4H LT4H-L LT4H-L PM4H-W PM4H-A (Signal) PM4H-A PM4H-F PM5S-A PM5S-A (Signal) PM5S-M PM5S-M (Signal) S1DX S1DXM-M S1DX S1DXM-M One-shot Star delta One-cycle LT4H LT4H-L PM4H-SD/SDM S1DX PM4H-A PM5S-A PM5S-M S1DX S1DXM-M S1DX S1DX S1DXM-M Integration LT4H LT4H-L ...

Page 13

TIMERS SELECTOR CHART Power ON-delay Operation mode For time control for short Major uses or long time 1000h 100h 30h 10h 1h Time range 30m 10m Each model has various 5m time ranges. See the 2m 1m product lists before ...

Page 14

... Output with contact CR oscillation counting timer For highly accurate time setting 10h 60min 30min 10min 3s 0.2s 0.5s 0.05s S1DXM-A/M Timer With a large transparent dial. This timer can be attached both on the DIN rails and panel Form C type 4 Form C type 250 V AC Terminal block, cap block, ...

Page 15

Power ON-delay Power flicker Power One-shot Operation mode Power One-cycle Output with contact CR oscillation counting timer Major uses For highly accurate time setting 1000h 100h 30h 10h 1h Time range 30m 10min 10m Each model has various 5m 3min ...

Page 16

TIMERS SELECTOR CHART Operation mode Major uses Suitable for high accurate, long time uses 1000h 100h 30h 10h 1h Time range 30m 10m Each model has various 5m time ranges. See the 2m 1m product lists before 30s 30s ordering. ...

Page 17

ON-DELAY TIMER BASIC CIRCUIT ( Symbols ) Self-resetting switch Relay NO contact Holding switch Relay NC contact R Relay Timer delay NO contact T Timer Timer delay NC contact L Load Timer instantaneous NO contact Timer in work Timer instantaneous ...

Page 18

... OFF Power supply ( In time delay operation ) ON OFF Output signal ( Time delay contact ) Operating time • Flicker Operation The flicker operation is an operation to repeat output ON/OFF action according to preset ON time and OFF time while a predetermined input is given to the power supply circuit or input circuit. ...

Page 19

Pause Time Error It means the difference between the operating time to a fixed pause time and the operating time to a pause time that varies. The pause time characteristics are the main characteristics of CR timer (timer exploiting ...

Page 20

PRECAUTIONS IN USING THE TIMERS Cautions for circuits 1. Protective circuit for timer contact In the circuit that switches an inductive load, a contact failure may occur at a contact point due to surge or inrush current resulting from that ...

Page 21

If the timer is directly switched with a non-contact element, leak current may flow into the timer and cause it to mal- function. 6. Power off time If the operation voltage for the timer is turned ON after the ...

Page 22

PRECAUTIONS IN USING THE TIMERS 7. Operating environment 1) Use the timer within the ambient tem- perature range from –10°C to +50°C +14°F to +122°F (+55°C +131°F for the LT4H series) and at ambient humidity of 85% RH maximum. 2) ...

Page 23

DISCONTINUED MODELS AND RECOMMENDED SUBSTITUTES Timers Discontinued models Recommended substitutes MHP-NS Exposed type MHP-N Exposed type Square plug-in/ Round plug-in/ horizontal type vertical type MHP-NS- MHP-N- MHP-M Exposed type MHP-NM Exposed type Round plug-in/ Round plug-in/ horizontal type vertical type ...

Page 24

... PM48W PM4HW- PMH-M PM4H-M/PM4S PMH-M- PM4HM-/PM4S- CDX Time relay S1DXM-A Timer/ S1DX Timer CDX S1DXM-/S1DX- PDX Timer S1DXM-A Timer/ S1DX Timer PDX S1DXM-/S1DX- VHP digital high-power timer QM4H digital timer VHP QM4H QM48S (8-pin) QM4H (8-pin) QM48S QM4H ...

Page 25

Counters Discontinued models Recommended substitutes MC electromagnetic LC4H counters LC4H MC6 LC4H-L LC48 Relay type: 8-pin LC4H Relay type: 8-pin Tr type: 11-pin Tr type: 11-pin LC4H LC48 LC4H-L LC48W (11-pin) LC4H-W (11-pin) LC48W LC4H-W EM48S (8-pin) LC4H (8-pin) LC4H ...

Page 26

FOREIGN SPECIFICATIONS OVERVIEW 1. International Standards IEC standard International Electrotechnical Commission By promoting international cooperation toward all problems and related issues regarding standardization in the electrical and electronic technology fields, the IEC, a non-governmental organization, was started in October, 1908, ...

Page 27

Pilot Duty One of the specifications in the “UL508 Industrial Control Equipment” regulations at UL (Underwriters Laboratories Inc.), has to do with the grade of contact control capacity by NEMA (National Electrical Manufacturers Association) standards. By obtaining both UL ...

Page 28

... QM4H PILOT DUTY C300 E59504 7A1/6HP125VAC 7A1/6HP250VAC 3A30VDC PMH PILOT DUTY C300 MHP E59504 5A250VAC MHP-M E122222 7A125VAC 6A250VAC 2C S1DXM- 1/6HP125, 250VAC A/M PILOT DUTY C300 (Relay E122222 5A250VAC output) 4C 1/10HP125, 250VAC PILOT DUTY C300 E122222 7A125VAC 6A250VAC 2C 1/6HP125, 250VAC S1DX ...

Page 29

FOREIGN SPECIFICATIONS Counters UL recognized Product name File No. Approved ratings E122222 5A250V AC LC4H PILOT DUTY C300 LC4H-L LC4H-S 100mA 30V DC E122222 3A250V AC PILOT DUTY C300 LC4H-W 100mA 30V DC E122222 24-240 V AC/DC LC2H 4.5-30 V ...

Page 30

... Product Product name classification LT4H EN 61000-6-4/EN 61000-6-2 LT4H-L EN 61000-6-4/EN 61000-6-2 LT4H-W EN 61000-6-4/EN 61000-6-2 PM4H EN 61000-6-4/EN 61000-6-2 Timers S1DX EN 61000-6-4/EN 61000-6-2 S1DXM-A/M EN 61000-6-4/EN 61000-6-2 PM4S EN 61000-6-4/EN 61000-6-2 PM5S EN 61000-6-4/EN 61000-6-2 QM4H EN 61000-6-4/EN 61000-6-2 A-TB72 EN 61000-6-4/EN 61000-6-2 Time Switch A-TB72Q EN 61000-6-4/EN 61000-6-2 LC4H ...

Related keywords