DRSCN05 Crydom Co., DRSCN05 Datasheet

SOCKET DIN-RAIL 3-12VDC CN SER

DRSCN05

Manufacturer Part Number
DRSCN05
Description
SOCKET DIN-RAIL 3-12VDC CN SER
Manufacturer
Crydom Co.
Series
DRSCNr
Type
Socketr
Datasheets

Specifications of DRSCN05

Number Of Positions
4
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Socket Mounting
DIN Rail
Current Rating
6A
Voltage Rating
250V
Accessory Type
Relay Socket
Rohs Compliant
Yes
For Use With/related Products
CN Series
For Use With
CC1744 - RELAY SSR 2A 240VAC 4SIPCC1742 - RELAY SSR 3.5A 24VDC 4SIPCC1796 - RELAY SSR 0.1A 48VDC 4SIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DRACN Series
PRODUCT SELECTION
Description
3-12 VDC
15-30 VDC
90-140 VAC (6)
190-250 VAC (6)
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage
Maximum Load Current @ 40°C (2)
Minimum Load Current [mA]
Maximum Blocking Voltage
Maximum Surge Current [Apk]
Maximum I²t for fusing 50/60Hz (1/2 cycle) [A² sec]
Typical On-State Voltage Drop @ Rated Current (V)
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Maximum PWM (Hz) (3)
Switch Configuration
• 6.2mm Din-Rail Mount (35 mm) SSR Assembly
• Ratings 24VDC @ 3.5A, 48VDC @ 100mA and 240VAC @ 2A
• 5 & 24 VDC and 120V & 240 VAC Control (6)
• UL & cUL recognized @ 40°C, 100K-Cycle Endurance Test (SSR Only)
• AC output SSR is UL rated for Pilot Duty @ 240VAC
• CE & RoHS Compliant
• Yellow LED input status indicator
DRA-CN024D120
DRA-CN024D240
DRA-CN024D05
DRA-CN024D24
3.5 A
DRA-CN024DXX
9 A (10 ms)
0-24 VDC
30 VDC
0.001
3.5 A
N.O.
N.A.
500
0.4
1
DRA-CN048D120
DRA-CN048D240
DRA-CN048D05
DRA-CN048D24
100 mA
DRA-CN048DXX
300 mA (10 ms)
0-48 VDC
100 mA
60 VDC
DRA-CN240A120
DRA-CN240A240
0.001
DRA-CN240A05
DRA-CN240A24
N.A.
N.O.
500
1.0
1
2 A
120/115 A (16.6/20 ms)
DRA-CN240AXX
24-250 VAC
600 VAC
285/260
N.A.
N.O.
2 A
70
1.1
4.0

Related parts for DRSCN05

DRSCN05 Summary of contents

Page 1

DRACN Series • 6.2mm Din-Rail Mount (35 mm) SSR Assembly • Ratings 24VDC @ 3.5A, 48VDC @ 100mA and 240VAC @ 2A • 5 & 24 VDC and 120V & 240 VAC Control (6) • UL & cUL recognized @ ...

Page 2

INPUT SPECIFICATIONS for CN024 (1) Description Control Voltage Range Must Turn On Voltage Must Turn Off Voltage Nominal Input Impedance Typical Input Current Typical Turn-On Time Typical Turn-Off Time INPUT SPECIFICATIONS for CN048 (1) Description Control Voltage Range Must Turn ...

Page 3

MECHANICAL SPECIFICATIONS THERMAL DERATE INFORMATION ...

Page 4

AGENCY APPROVALS AC output relay is UL rated for Pilot Duty @ 240VAC ACCESSORIES Rev. 120910 ...

Page 5

...

Page 6

ANNEX - ENVIROMENTAL INFORMATION ...

Related keywords