HP3-SF Panasonic Electric Works, HP3-SF Datasheet

no-image

HP3-SF

Manufacturer Part Number
HP3-SF
Description
SOCKET TERM W/CLIP SCREW FOR HP3
Manufacturer
Panasonic Electric Works
Series
HPr
Type
Socketr
Datasheet

Specifications of HP3-SF

Number Of Positions
11
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Features
Mounting Hardware
For Use With/related Products
HP3 Relays
For Use With
HP3-L-AC100V - RELAY PWR 3PDT 10A 100VAC PLUGINHP3-L-DC48V - RELAY PWR 10A 48VDC WIRED/PLUGINHP3-L-DC24V - RELAY PWR 10A 24VDC WIRED/PLUGINHP3-L-DC110V - RELAY PWR 10A 110VDC WIRE/PLUGINHP3-L-AC24V - RELAY PWR 10A 24VAC WIRED/PLUGINHP3-L-AC115V - RELAY PWR 10A 115VAC WIRE/PLUGINHP3-DC48V - RELAY POWER 10A 48VDC PLUG-INHP3-DC24V - RELAY POWER 10A 24VDC PLUG-INHP3-DC12V - RELAY POWER 10A 12VDC PLUG-INHP3-DC110V - RELAY POWER 10A 110VDC PLUG-INHP3-AC24V-VDE - RELAY POWER 10A 24VAC VDE PLUGINHP3-AC24V - RELAY POWER 10A 24VAC PLUG-INHP3-AC240V - RELAY POWER 10A 240VAC PLUG-INHP3-AC115V - RELAY POWER 10A 115VAC PLUG-INHP3-AC110V - RELAY POWER 10A 110VAC PLUG-IN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available for easy visual confirmation that
relays are operating. They simplify
maintenance.
4. UL/CSA approved
5. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
http://www.mew.co.jp/ac/e/environment/
RoHS Directive compatibility information
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Transportation
Amplification of control signals in control
devices for vehicles and vessels,
functional parts of all kinds of equipment,
control signal repeating installation in
signaling devices and equipment.
7. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
8. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
10 AMP POWER RELAY
9. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
10. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 4 Form C
contact type. The 2 Form C and 3 Form C
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
HP RELAYS
HP

Related parts for HP3-SF

HP3-SF Summary of contents

Page 1

... They simplify maintenance. 4. UL/CSA approved 5. Wide range of sockets and terminal sockets To enable use with DIN rails, DIN terminal sockets are also available. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. ...

Page 2

... All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 3 Form C 4 Form C Part No. Part No. HP3-AC6V HP4-AC6V-F HP3-AC12V HP4-AC12V-F HP3-AC24V HP4-AC24V-F HP3-AC48V HP4-AC48V-F HP3-AC100V HP4-AC100V-F HP3-AC115V HP4-AC115V-F HP3-AC200V HP4-AC200V-F HP3-AC220V HP4-AC220V-F HP3-AC240V HP4-AC240V-F HP3-DC6V HP4-DC6V-F HP3-DC12V HP4-DC12V-F HP3-DC24V HP4-DC24V-F HP3-DC48V HP4-DC48V-F HP3-DC100V HP4-DC100V-F HP3-DC110V HP4-DC110V-F ...

Page 3

... HP3-ML-AC220V HP3-ML-AC240V HP3-ML-DC100V HP3-ML-DC110V HP 4 Form C Part No. HP4-L-AC6V-F HP4-L-AC12V-F HP4-L-AC24V-F HP4-L-AC100V-F HP4-L-AC115V-F HP4-L-AC200V-F HP4-L-AC220V-F HP4-L-AC240V-F HP4-L-DC6V-F HP4-L-DC12V-F HP4-L-DC24V-F HP4-L-DC48V-F HP4-L-DC100V-F HP4-L-DC110V-F 3 Form C (direct mount type) Part No. HP3-M-AC6V HP3-M-AC12V HP3-M-AC24V HP3-M-AC48V HP3-M-AC100V HP3-M-AC115V HP3-M-AC200V HP3-M-AC220V HP3-M-AC240V HP3-M-DC6V HP3-M-DC12V HP3-M-DC24V HP3-M-DC48V HP3-M-DC100V HP3-M-DC110V ...

Page 4

HP RATING 1. Coil data 1) AC coils Nominal coil current Contact Nominal coil (mA) arrangement voltage 50Hz 6V AC 349mA 12V AC 181.2mA 24V AC 94mA 48V AC 46.5mA 2 Form C 100V AC 25.3mA 115V AC 23.1mA 200V ...

Page 5

Specifications Characteristics Item Arrangement Initial contact resistance, max Contact 2 Form C, 3 Form C Contact material 4 Form C Nominal switching capacity Rating Min. switching capacity (Reference value)* Insulation resistance (Initial) Between open contacts Breakdown voltage Between contact ...

Page 6

... Coil terminal No. and polarity (DC type) Polarity HP2 (+) 7 Terminal No. (–) 2 Schematic (Bottom view Compatible with tab terminal #205 series receptacle. Tolerance .079 inch: 0.2 .008 .079 to .354 inch: 0.5 .020 .354 to .787 inch: 1 .039 .787 inch: 1.5 .059 HP3 HP4 ...

Page 7

Plug-in type (3 Form C) Plug-in type (4 Form C) 0.8 .031 9 10 5.26 .207 .207 All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. External dimensions 5 8 .197 .315 .197 38 1.496 0.5 .020 44 1.732 5 ...

Page 8

HP TM type (2 Form C) Dimension: Tolerance Max. 2mm .079 inch: 0.2 .008 2 to 9mm .079 to .354 inch: 0.5 .020 9 to 20mm .354 to .787 inch: 1 .039 Min. 20mm .787 inch: 1.5 .059 Direct mounting ...

Related keywords