Specifications of G6K-2F DC4.5

Coil Type
Standard
Coil Current
23.2mA
Relay Type
Telecom
Circuit
DPDT (2 Form C)
Contact Rating @ Voltage
1A @ 30VDC
Coil Voltage
4.5VDC
Control On Voltage (max)
3.6 VDC
Control Off Voltage (min)
0.45 VDC
Mounting Type
Surface Mount
Termination Style
Gull Wing
Contact Configuration
DPDT
Contact Current Max
1A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
4.5V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
G6K-2F-DC4.5
G6K2FDC4.5
G6K2FDC45
Z111
G6K
Engineering Data
4
Shock Malfunction
Shock direction
Maximum Switching Power
Endurance
Conditions:
DC resistive load
125 VAC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Shock is applied in ±X, ±Y, and ±Z di-
rections three times each with and with-
out energizing the Relays to check the
number of contact malfunctions.
30 VDC resistive load
Ambient temperature: 23°C
Switching frequency:
1,800 operations/hour
Switching voltage (V)
AC resistive load
Switching current (A)
Not
energized
Unit: m/s
Sample: G6K-2G
Number of Relays: 10
Energized
2
Note: The maximum coil voltage refers to the maxi
Electrical Endurance
(with Must Operate and Must Re
lease Voltage) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs. Must
Operate or Must Release Voltage
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Maximum Coil Voltage
Operating frequency (x10 operations)
Note: The tests were conducted at an
Must operate
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load at
30 VDC with an operation rate of 50%
Switching frequency: 1,800 operations/h
mum value in a varying range of operating
power voltage, not a continuous voltage.
Must release
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value
3
Must operate voltage
Must release voltage
Electrical Endurance
(Contact Resistance) (See note.)
G6K-2G (F/P), G6K-2G (F/P)-Y
Ambient Temperature vs.
Switching Current
Ambient Temperature vs. Must
Set or Must Reset Voltage
G6KU-2G (F/P)-Y
Operating frequency (x10
Note: The tests were conducted at an
Switching frequency: 1,800 operations/h
Sample: G6K-2G
Number of Relays: 10
Test conditions: 1 A resistive load
at 30 VDC with an operation rate of 50%
Contact resistance
ambient temperature of 23˚C.
Ambient temperature (°C)
Ambient temperature (°C)
Max. estimated value