70L-IAC Grayhill Inc, 70L-IAC Datasheet

I/O MODULE AC IN 120V DUAL

70L-IAC

Manufacturer Part Number
70L-IAC
Description
I/O MODULE AC IN 120V DUAL
Manufacturer
Grayhill Inc
Series
70r
Type
ACr
Datasheet

Specifications of 70L-IAC

Color
Gray
Style
OpenLine®
Voltage - Input
0 ~ 140VAC (120VAC Nom)
Current - Input
8mA
Logic Supply Voltage (output)
5VDC (4.5 ~ 28 VDC)
Logic Supply Current (output)
6mA
Turn On Time
20ms
Turn Off Time
20ms
Features
2 Channel, Status LED(s)
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Supply Voltage Min
4.5VDC
Supply Voltage Max
28VDC
No. Of Outputs
1
Brand/series
Open Line®
Connection To Host
Board Mount
Current, Input
6 mA
Input
0 to 140 VAC
Input Type
Analog
Input, Range
0 to 140 VAC
Module Type
Input
Mounting Type
PCB
Number Of Channels
2
Primary Type
Control
Resistance, Input
22 Kiloohms (Nom.)
Special Features
Optical Isolation
Standards
UL, CSA, CE, TUV Certified
Temperature, Operating
-40 to +85 °C
Time, Turn-off
20 ms
Time, Turn-on
20 ms
Voltage, Isolation
4000 VAC
Voltage, Operating
120
Voltage, Supply
5 VDC
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free by exemption / RoHS compliant by exemption
Other names
GH3058
FEATURES
• Transient Protection: Meets the
• UL, CSA, CE, TÜV Certified (TÜV
• Optical Isolation
• OpenLine
• Lifetime Warranty
CIRCUITRY
SPECIFICATIONS: By Package Style
1
2
3
I/O
14
requirements of IEEE 472, “Surge
Withstanding Capability Test”
not available on OpenLine)
Built-in Status LED
Field to logic and channel-to-channel if Grayhill racks are used.
MIL-STD-202, Method 204, 20 G, 10-2000 Hz or IEC68-2-6, 0.15 mm/sec
MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g.
Package Style
Specifications
Output Current Range
Minimum Output Breakdown Voltage
Maximum Turn-On Time
Maximum Turn-Off Time
Isolation Voltage
Vibration
Mechanical Shock
Storage Temp. Range
Operating Temp. Range
Warranty
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
2
®
+
VDC
+VCC
OUTPUT
GROUND
and G5 Modules have
Status LED in G5 modules only.
Standard, Mini, G5
1
3
1
2
3
4
5
AC Input Modules
REGULATING
Rx
CURRENT
HYST. CIRC.
VOLTAGE
INPUT
Units
Vrms
Vdc
mA
mS
mS
°C
°C
TERMINAL
BLOCK #
*
I/O MODULE
PIN #
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
DEVICE
DEVICE
INPUT
INPUT
Std (70-)
Lifetime
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
4000
1-50
50
20
20
1
2
3
4
BASE
RACK
OR
70L-IAC
1
2
3
4
2
, 10-150 Hz.
TYPICAL WIRING FOR MODULE 70
MIL-STD-202
MIL-STD-202
*
Mini (70M-)
-40 to +125
-40 to +100
Separate supplies may also be used.
Lifetime
4000
1-50
FILTER
FILTER
50
20
20
OpenLine
ISOLATION
ISOLATION
OPTICAL
OPTICAL
70G-IAC
MODULE
®
HYSTERESIS
MIL-STD-202
MIL-STD-202
-40 to +125
-40 to +100
G5 (70G-)
Lifetime
HYSTERESIS
A
4000
1-50
50
20
20
70-IAC
B
0Ω
6
7
5
8
9
IEC68-2-27
-40 to +100
Vcc
CH. A STATUS
GND
CH. B STATUS
MODULE ID
OL (70L-)
IEC68-2-6
-40 to +85
Lifetime
70M-IAC
2500
1-50
50
20
20

Related parts for 70L-IAC

70L-IAC Summary of contents

Page 1

... Field to logic and channel-to-channel if Grayhill racks are used. 2 MIL-STD-202, Method 204 10-2000 Hz or IEC68-2-6, 0.15 mm/sec 3 MIL-STD-202, Method 213, Condition F, 1500 G or IEC68-2-27, 11 mS, 15g. I/O 14 Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 70L-IAC OpenLine I/O MODULE TYPICAL WIRING FOR MODULE 70 PIN # INPUT 1 1 ...

Page 2

... W 22K 60K 22K Vac 90 180 Vac 25 50 Vdc 5 5 Vdc 4.5-6 4.5-6 10- Grayhill Part Number 70L-IAC 70L-IACA Units Vac 120 240 Vac/Vdc 0-140 0-280 mA, rms 22K 64K Vac 90 180 Vac 25 50 Vdc 5 5 Vdc 4.5-28 4.5-28 mA 6/CH ...

Related keywords