HS2214EPI62H Renesas Electronics America, HS2214EPI62H Datasheet

no-image

HS2214EPI62H

Manufacturer Part Number
HS2214EPI62H
Description
EMULATOR BASE UNIT H8S/2214
Manufacturer
Renesas Electronics America
Type
Microcontrollerr
Datasheets

Specifications of HS2214EPI62H

Contents
E6000 Emulator and CD-ROM
For Use With/related Products
H8S/2214
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
To our customers,
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry.
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Renesas Electronics website:
Old Company Name in Catalogs and Other Documents
http://www.renesas.com
April 1
Renesas Electronics Corporation
st
, 2010

Related parts for HS2214EPI62H

HS2214EPI62H Summary of contents

Page 1

To our customers, Old Company Name in Catalogs and Other Documents st On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the ...

Page 2

All information included in this document is current as of the date this document is issued. Such information, however, is subject to change without any prior notice. Before purchasing or using any Renesas Electronics products listed herein, please confirm ...

Page 3

IMPORTANT INFORMATION • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. User ...

Page 4

LIMITED WARRANTY Hitachi warrants its user system interface cables to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Hitachi will repair or replace any user system interface cables determined to be defective in ...

Page 5

State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and ...

Page 6

READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL ...

Page 7

WARNING Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST ...

Page 8

H8S/2212 Series FP-64E User System Interface Cable (HS2212ECH61H) for E6000 Emulator User’s Manual Rev.1.0 2003.02 ...

Page 9

Hitachi neither warrants nor grants licenses of any rights of Hitachi’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Hitachi bears no responsibility for problems that may arise with ...

Page 10

... H8S/2212 Series. The HS2212ECH61H is a user system interface cable that connects an H8S/2214 series E6000 emulator (HS2214EPI62H; hereinafter referred to as the emulator) to the IC socket for a FP-64E package for the H8S/2212 series MCU on the user system. The user system interface cable should be used with H8S/2214 series E6000 emulator (HS2214EPI62H: hereinafter referred to as the emulator) ...

Page 11

Section 1 Configuration....................................................................................1 Section 2 Connection Procedures ......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station ......................................... 3 2.2 Connecting User System Interface Cable to User System ................................................ 5 2.2.1 Installing IC Socket ............................................................................................. 5 2.2.2 Soldering IC Socket ...

Page 12

Section 1 Configuration Use an IC149-064-175-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on the user system. Figure 1 shows the configuration of the HS2212ECH61H user system interface cable for the FP-64E package. To ...

Page 13

Table 1 lists the HS2212ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS2212ECH61H Components No. Component 1 Cable body 2 Cable head 3 IC socket 4 Socket cover 5 Screws ( ...

Page 14

Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure will result in a FIRE HAZARD and will damage the user system and the emulator product or will ...

Page 15

Emulator station Screws for fixing the cable body Figure 2 Connecting User System Interface Cable to Emulator Station 4 Cable body connector User system interface cable ...

Page 16

Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 ...

Page 17

Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a FP-64E package on the user system with pin 1 on the user system interface cable head, and insert the ...

Page 18

Pin 1 User system Figure 3 Connecting User System Interface Cable to User System Screws ( mm) with flat washers Cable head IC socket (IC149-064-175-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 7 ...

Page 19

Fastening Cable Body Connect the cable body to the cable head. Cable body Remove jig User system Figure 4 Fastening Cable Body 8 Removing Push the remove jig Cable head ...

Page 20

Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a FP-64E package (IC149-064-175-B51: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that ...

Page 21

Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 10 25.0 19.3 63.5 Unit: mm Tolerance: ±0.5 mm ...

Page 22

Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Cable head IC socket (IC149-064-175-B51 User system manufactured by YAMAICHI ELECTRONICS ...

Page 23

Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.29 N•m or less. If ...

Page 24

Screws ( mm) with flat washers Pin 1 User system Figure 8 Installing MCU to User System Socket cover MCU IC socket (IC149-064-175-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) 13 ...

Page 25

... The user system interface cable includes the H8S/2218 microcomputer to emulate the USB function. The H8S/2212 user interface signal includes a interface circuit as shown in figure 9. H8S/2218 DrVcc 0.1 F DrVss USD+ USD- UBPM VBUS USPND D15 to D8 E6000 emulator HS2214EPI62H Evaluation chip Vcc Vcc D15/PD7 to D8/PD0 Figure 9 User Interface Signal 14 HS2212ECH61H 0 ...

Page 26

... The emulator connected to this user system interface cable supports two kinds of clock sources as the MCU clock: an emulator internal clock and an external clock on the user system. For details, refer to the H8S/2214 E6000 Emulator User’s Manual (HS2214EPI62HE).  To use the emulator internal clock Select the clock in the emulator station with the [CLOCK] option in the [Configuration Properties] dialog box ...

Page 27

... The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS2214EPI62H emulators. Do not use this cable with any other emulator station prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the user system interface cable ...

Page 28

In the H8S/2212 series, the USB control register and the RTC control register are allocated to external bus areas of area 6 (H’C00000 to H’DFFFFF) and area 7 (H’E00000 to H’FFFFFF), respectively. To access these registers, a bus controller ...

Related keywords