AD8225-EVALZ Analog Devices Inc, AD8225-EVALZ Datasheet - Page 13

no-image

AD8225-EVALZ

Manufacturer Part Number
AD8225-EVALZ
Description
BOARD EVAL FOR AD8225 INSTR AMP
Manufacturer
Analog Devices Inc
Datasheets

Specifications of AD8225-EVALZ

Channels Per Ic
1 - Single
Amplifier Type
Instrumentation
Output Type
Single-Ended
Slew Rate
5 V/µs
-3db Bandwidth
900kHz
Current - Output / Channel
18mA
Operating Temperature
-40°C ~ 85°C
Current - Supply (main Ic)
1.05mA
Voltage - Supply, Single/dual (±)
3.4 V ~ 36 V, ±1.7 V ~ 18 V
Board Type
Fully Populated
Utilized Ic / Part
AD8225
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
In the classical three op amp in amp topology shown in Figure 8,
gain is developed differentially between the two input amplifiers
A1 and A2, sacrificing CMV (common-mode voltage) range.
The gain of the in amp is typically 10 or less, and an additional
gain stage increases the overall gain to approximately 1000.
Gain developed in the input stage results in a trade-off in common-
mode voltage range, constraining the ability of the amplifier to
tolerate high dc electrode errors. Although the AD8225 is also
a three amplifier design, its gain of 5 is developed at the output
amplifier, improving the CMV range at the input. Using ± 5 V
supplies, the CMV range of the AD8225 is from –3.4 V to
+4 V, compared to –3.1 V to +3.8 V, a 7% improvement in
input headroom over conventional in amps with the same gain.
Figure 9 illustrates how an AD8225 may be used in an EKG
front end. In a low cost system, the AD8225 can be connected to
the patient. If buffers are required, the AD8225 can replace the
expensive precision resistor network and op amp.
Figure 10 shows test waveforms observed from the circuit of
Figure 9.
REV. A
Figure 9. EKG Monitor Front End
AD8225
AD8225
AD8225
100
100
100
G = 5
G = 5
G = 5
19.6k
19.6k
19.6k
OP77
OP77
OP77
G = 200
G = 200
G = 200
301
301
301
–13–
Benefits of Fast Slew Rates
At 5 V/µs, the slew rate of the AD8225 is as fast as many op amp
circuits. This is an advantage in systems applications using multiple
sensors. For example, an analog multiplexer (see Figure 11) may
be used to select pairs of leads connected to several sensors. If
the AD8225 drives an ADC, the acquisition time is constrained
by the ability of the in amp to settle to a stable level after a new
set of leads is selected. Fast slew rates contribute greatly to
this function, especially if the difference in input levels is large.
Figure 12 illustrates the response of an AD8225 connected to
an ADG409 analog multiplexer in the circuit shown in Figure 11
at two signal levels. Two of the four MUX inputs are connected
to test dc levels. The remaining two are at ground potential so
that the output slews as the inputs A0 and A1 are addressed. As
can be seen, the output response settles well within 4 µs of the
applied level.
Figure 10. EKG Waveform Using Circuit of Figure 9
Figure 11. Connection to an ADG409 Analog MUX
Figure 12. Slew Responses After MUX Selection
0.2V, 2V
RA-LA 1
RA-LL 3
LA-LL 2
CH 1 = 200mV, CH 2 = 2V, H = 500ns
SIGNAL
SITION
TRAN-
INPUT
CH 1 = 2V, CH 2 = 2V, CH 3 = 2V, H = 200ms
S1A
S1B
S2A
S2B
S3A
S3B
S4A
S4B
LARGE SIGNAL
(2V/DIV)
SMALL SIGNAL
(200mV/DIV)
ADG409
DA
DB
1
4
AD8225
AD8225
REF