DAK-68A Power Integrations, DAK-68A Datasheet - Page 25

KIT DESIGN ACCELERATOR POE CONV

DAK-68A

Manufacturer Part Number
DAK-68A
Description
KIT DESIGN ACCELERATOR POE CONV
Manufacturer
Power Integrations
Series
DPA-Switch®r
Datasheets

Specifications of DAK-68A

Main Purpose
Special Purpose DC/DC, Power Over Ethernet
Outputs And Type
1, Non-Isolated
Power - Output
6.6W
Voltage - Output
3.3V
Current - Output
2A
Voltage - Input
36 ~ 57V
Regulator Topology
Flyback
Frequency - Switching
400kHz
Board Type
Bare (Unpopulated) and Fully Populated
Utilized Ic / Part
DPA423, DPA424, DPA425
Lead Free Status / RoHS Status
Not applicable / Not applicable
Other names
596-1007
NOTES:
A.
B.
C.
D.
www.powerint.com
Supply Voltage Characteristics
DRAIN Supply Voltage
Shunt Regulator
Voltage
Shunt Regulator
Temperature Drift
CONTROL Supply/
Discharge Current
For specifi cations with negative values, a negative temperature coeffi cient corresponds to an increase in magnitude with increas-
ing temperature, and a positive temperature coeffi cient corresponds to a decrease in magnitude with increasing temperature.
For externally adjusted current limit values, please refer to Figure 35 (Current Limit vs. External Current Limit Resistance) in the
Typical Performance Characteristics section.
Breakdown voltage may be checked against minimum BV
exceeding minimum BV
It is possible to start up and operate DPA-Switch at DRAIN voltages well below 16 V. However, the CONTROL pin charging
current is reduced, which affects start-up time, auto-restart frequency, and auto-restart duty cycle. Refer to Figure 45, the
characteristic graph on CONTROL pin charge current (I
Parameter
DSS
Symbol
.
V
C(SHUNT)
I
I
CD1
CD2
MOSFET Enabled
SOURCE = 0 V; T
f
OSC
V
(Unless Otherwise Specifi ed)
Output
= 400 kHz
L
I
C
= 0 V;
Output MOSFET Disabled
V
= (I
L
= 0 V; f
C(skip)
I
C
See Figure 33
Conditions
See Note D
= (I
C
) vs. DRAIN voltage for low voltage operation characteristics.
+ I
C(skip)
DSS
OSC
B
)/2; T
J
specifi cation by ramping the DRAIN pin voltage up to but not
= 400 kHz
+ I
= -40 to 125 °C
B
J
)/2
= 25 °C
DPA422
DPA423
DPA424
DPA425
DPA426
Min
5.6
1.6
1.9
2.6
3.7
4.8
0.4
16
5.85
0.73
Typ
±50
2.0
2.3
3.0
4.3
5.4
DPA422-426
Max
6.0
2.4
2.7
3.4
4.8
1.2
6
PPM/°C
Units
Rev. S 12/07
mA
V
V
25

Related parts for DAK-68A