HI7190EVAL Intersil, HI7190EVAL Datasheet - Page 4

no-image

HI7190EVAL

Manufacturer Part Number
HI7190EVAL
Description
EVALUATION PLATFORM HI7190
Manufacturer
Intersil
Datasheets

Specifications of HI7190EVAL

Number Of Adc's
1
Number Of Bits
24
Sampling Rate (per Second)
200k
Data Interface
Serial
Inputs Per Adc
1 Differential
Input Range
±2.5 V
Power (typ) @ Conditions
15mW @ 200kSPS
Voltage Supply Source
Analog and Digital, Dual ±
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
HI7190
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
s
c
w Entering w from the Main Menu brings the Write Menu
r
x
Change Mode Menu:
1 Self Calibration - 10Hz
2 Self Calibration - 2kHz
3 System Offset Calibration - 10Hz
4 System Positive Full Scale Calibration - 10Hz
5 System Negative Full Scale Calibration - 10Hz
c
r
w Write Menu
m Main Menu
x
1 Entering 1 from the Change Mode Menu initiates a com-
2 Entering 2 from the Change Mode Menu initiates a com-
3 Entering 3 from the Change Mode Menu initiates a com-
4 Entering 4 from the Change Mode Menu initiates a com-
Entering s from the Main Menu sends an active low reset
signal to the HI7190 which initializes the HI7190.
Entering c from the Main Menu brings the Change Mode
Menu up. The Change Mode Menu allows the user to
custom configure the HI7190 without having to know the
bit positions of the Control Register.
up. The Write Menu allows the user write access to all
writable registers without having knowledge of specific
Instruction Register address details.
Entering r from the Main Menu brings the Read Menu up.
The Read Menu allows the user to read all registers
without having knowledge of specific Instruction Register
address details.
Entering x from the Main Menu exits the program.
Custom Menu
Read Menu
Exit Program
munication cycle with the HI7190 that invokes the Self
Calibration Mode with a notch frequency of 10Hz. Other
operating parameters are offset binary coding, bipolar
mode and a gain of one. Executing this command
returns the user to the Main Menu.
munication cycle with the HI7190 that invokes the Self
Calibration Mode with a notch frequency of 2kHz. Other
operating parameters are offset binary coding, bipolar
mode and a gain of one. Executing this command
returns the user to the Main Menu.
munication cycle with the HI7190 that invokes the Sys-
tem Offset Calibration Mode with a notch frequency of
10Hz. Other operating parameters are offset binary cod-
ing, bipolar mode and a gain of one. Please note, the
user should apply 0V to the HI7190 inputs before issuing
this command. Executing this command returns the user
to the Main Menu.
munication cycle with the HI7190 that invokes the Sys-
tem Positive Full Scale Calibration Mode with a notch
frequency of 10Hz. Other operating parameters are off-
set binary coding, bipolar mode and a gain of one.
Please note, the user should apply the positive full scale
voltage to the HI7190 inputs before issuing this com-
mand. Executing this command returns the user to the
Main Menu.
Application Note 9505
4
5 Entering 5 from the Change Mode Menu initiates a com-
c
r
w Entering w from the Change Mode Menu invokes the
m Entering m from the Change Mode Menu invokes the
x
Write Menu:
1 Command Register
2 Offset Register
3 Positive Full Scale Register
4 Negative Full Scale Register
m Main Menu
r
x
1 Entering 1 from the Write Menu invokes a write commu-
2 Entering 2 from the Write Menu invokes a write commu-
3 Entering 3 from the Write Menu invokes a write commu-
4 Entering 4 from the Write Menu invokes a write commu-
munication cycle with the HI7190 that invokes the Sys-
tem Negative Full Scale Calibration Mode with a notch
frequency of 10Hz. Other operating parameters are off-
set binary coding, bipolar mode and a gain of one.
Please note, the user should apply the negative full scale
voltage to the HI7190 inputs before issuing this com-
mand. Executing this command returns the user to the
Main Menu.
Entering c from the Change Mode Menu allows the user
to customize the operational parameters of the HI7190.
The user will be asked a series of questions relating to
HI7190 operation. After completing these questions, the
software compiles the proper data and writes the Control
Register to invoke the desired operating mode. Execut-
ing this command returns the user to the Main Menu.
Entering r from the Change Mode Menu invokes the
Read Menu.
Write Menu.
Main Menu.
Entering x from the Change Mode Menu exits the pro-
gram.
Read Menu
Exit Program
nication cycle with the Control Register. The user will be
prompted for the data to write. The software requires the
data be entered in hex, most significant to least signifi-
cant format. The Control Register is 3 bytes. All three
bytes must be entered at the prompt.
nication cycle with the Offset Calibration Register. The
user will be prompted for the data to write. The software
requires the data be entered in hex, most significant to
least significant format. The Offset Calibration Register is
3 bytes. All three bytes must be entered at the prompt.
nication cycle with the Positive Full Scale Calibration
Register. The user will be prompted for the data to write.
The software requires the data be entered in hex, most
significant to least significant format. The Positive Full
Scale Calibration Register is 3 bytes. All three bytes
must be entered at the prompt.
nication cycle with the Negative Full Scale Calibration
Register. The user will be prompted for the data to write.
The software requires the data be entered in hex, most

Related parts for HI7190EVAL